background image

AMPLIFIER LOCATION 

The location of the amplifier should be care-

fully selected and in the interest of passive dri-
ver and passenger safety, the amplifier must
also be securely mounted. Check the suitability
of your preferred amplifier location carefully,
before starting the installation. Preferably,
amplifiers are  mounted in the trunk compart-
ment of the car. The actual mounting surface
should be completely flat.

Please note that the amplifier location must

allow for a good airflow across and through
the amplifier housing. The air inlet for the
power supply ventilation is hidden underneath
the detachable side panel on the audio signal
input side of the amplifier. Adequate ventilation
will optimize the performance of the X-PULSE
amplifier and improve long-term stability dra-
matically.

In lack of a stable and flat mounting surface

you may also use a board made from ply-wood
or MDF (medium density fibre-board).

Make sure there is no wiring harness, fuel

tank etc. behind or below the mounting surfa-
ce, that may be damaged by the drilling of the
holes for the amplifier mounting screws.

Make sure the amplifier is not exposed to

dust (fan!) direct sunlight, humidity, water, oil or
spill of other fluids that may enter the amplifier.

Ideally after installation there should be a

clearance of at least 5 cm on all sides inclu-
ding the fan outlet on top of the amplifier.

Even after mounting is completed the ampli-

fier should allow easy access of all controlling
elements on the top panel of the amplifier and
– in case of the XP800.1 – the access to the
side panel is crucial too, because all the con-
trol knobs are located there.

MOUNTING

Remove the side panels from the amplifier as
shown in the explosion drawing, using the sup-

plied Allen hex-head wrench, in order to
access the four mounting holes on the four
outside corners of the amplifer.

Use the amplifier as a template for the marking
of the mounting holes on the selected moun-
ting surface with pencil or felt-tip.

Pilot-drill the mounting holes on the mounting
surface using a 2,5 mm or 3 mm drill.

Mount the amplifier in place using the supplied
selftapping screws and the rubber grommets
(see drawing for reference). The rubber grom-
mets protect the amplifier from excess vibrati-
ons and electrical ground-loops, that could
result in audible hum. Secure the amplifier in
its position by tightening the screws evenly
and re-check proper fit after completion.

IMPORTANT NOTICE! 
Disconnect the positive battery terminal
(+12V) or remove the main fuse near the car
battery before you start with any wiring work!

Please note that the power supply of the car
must remain disconnected until the entire
wiring installation is completed. 

Power Cables 

The minimum recommended power cable
cross-section (average cable length: 5 m) of
the main power supply cable – to obtain full
power output from the XP600.4 / XP700.5 and
XP800.1 - is 20 mm

2

. This applies for both +12V

and chassis ground (GND) connection power
cables. Using main power cables with smaller
cross-sections will result in lower power out-
put - especially with 1 or 2 ohms subwoofer
load - and may cause unnecessary over-hea-
ting of the amplifier circuitry, elevated distorti-
on at high volume levels or it may even trigger
the thermal protection circuitry, to shut-off the
amplifier.

Basic Wiring Installation and Cable
Routing Tips! 

Use rubber grommets when running cables
through any metal or sharp plastic to prevent

CONNECTING THE 

X-PULSE AMPLIFIER

MOUNTING THE 

X-PULSE AMPLIFIER

26

Ne2 XP6004/7005/8001 RZ (D+UK)  16.08.2000 6:32 PM  Seite 26

Содержание XP600.4

Страница 1: ...INSTALLATIONS BEDIENUNGSANLEITUNG INSTALLATION OPERATING MANUAL S t a t e o f t h e a r t Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 32 PM Seite 1 ...

Страница 2: ...2 Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 32 PM Seite 2 ...

Страница 3: ...System Configurations XP600 4 32 System Configurations XP700 5 35 System Configurations XP800 1 38 Tips fpr Input Level Settings 30 Technical Specifications 39 Warranty Conditions Warranty Card 40 Wir beglückwünschen Sie zum Erwerb Ihres X Pulse Verstärkers Dieser Car Amp ist das Ergebnis einer Entwicklungsarbeit in welcher diverse neuartige bisher auf dem Car Hifi Sektor in dieser Form nicht verw...

Страница 4: ...nzung des X PULSE Ver stärkerprogrammes dar Der Hauptvorteil der bei der XP800 1 und XP700 5 eingesetzten digitalen Verstärker Technologie liegt in der nahezu verlustfreien Verstärkung verbunden mit einem extrem hohen Wirkungsgrad Die hohe Effizienz stellt sicher dass ca 80 der von der Batterie bzw vom Alternator abgegebenen Leistung auch in entsprechende Verstärkerleistung umgewan delt wird und n...

Страница 5: ...her dass eine perfekte Anpassung der akustischen Phase des angeschlossenen Subwoofers an das Frontsystem möglich ist Die zusätzliche Basspegel Fernbedienung der XP800 1 und der XP700 1 ermöglicht eine sehr praxisgerechte und einfache Einstellung des Basspegels vom Fahrersitz aus Bewahren Sie dieses Manual zusammen mit der Kaufquittung für eventuell später auftau chende Fragen respektive Anschluss ...

Страница 6: ...1 3 5 0 4 9V 0 2V LEVEL 1 2CH X OVER 100 135 50 40 175 35Hz 200Hz LOWPASS 36 40 32 20 45 10Hz 50Hz SUBSONIC LEVEL 1 8 1 3 5 0 4 9V 0 2V 135 180 100 55 195 40Hz 200Hz HIGHPASS 135 180 100 55 195 40Hz 200Hz HIGHPASS 36 40 32 20 45 10Hz 50Hz HI FULL LOW HI FULL LOW 16 19 15 18 20 17 Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 32 PM Seite 6 ...

Страница 7: ...fz Batterie REM Remote Anschlussterminal zum Anschluss an den Remote Ausgang des Head Units BAT 12V 12 V Power Terminal für den Anschluss an den 12 V Pluspol der Kfz Batterie FUSE Interne Absicherung der Endstufe durch zwei 40 Ampere ATC Sicherungen LEVEL Regler zur Anpassung der Eingangsempfindlichkeit der Kanäle 3 4 CH im Bereich von 0 2V bis 9V SUBSONIC Regler zur Einstellung der Subsonic Hochp...

Страница 8: ... 175 35Hz 200Hz 2 1 3 5 0 5 9V 0 2V HI PASS 2CH 4CH 5CH 1 2CH X OVER 1 2CH LEVEL FRONT HP FULL HP BP 3 4CH X OVER HI PASS FULL 3 4CH LEVEL REAR PHASE SHIFT SUBSONIC 5CH LEVEL INPUTMODE LOW PASS 2 1 4 6 0 5 9V 0 2V LOW PASS OVERLOAD 2 3 4 1 5 5 CH 6 7 8 9 10 11 22 21 23 24 12 BEDIENUNGSELEMENTE XP700 5 17 18 16 20 14 19 15 13 Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 32 PM Seite 8 ...

Страница 9: ...rie REM Remote Anschlussterminal zum Anschluss an den Remote Ausgang des Steuergerätes BAT 12V 12 V Power Terminal für den Anschluss an den 12 V Pluspol der Kfz Batterie FUSE Interne Absicherung der Endstufe durch zwei 30 Ampere ATC Sicherungen PHASE SHIFT Regler zur Einstellung der akustischen Phase der Kanäle 5 6 CH Subwoofer respektive Anpassung der absoluten Phase des angeschlossenen Subwoofer...

Страница 10: ...5 10Hz 45 47 50Hz 140 90 50 35Hz 160 180 200Hz 0 6 1 4 3 8 9V 0 35 0 25 0 2V 3b 3a 4 5 1 6 7 8 9 SP SP 10a 10b 11 12 13 14 BEDIENUNGSELEMENTE XP800 1 2a 2b Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 32 PM Seite 10 ...

Страница 11: ...ter liegt immer im Signalweg es lässt sich nicht deaktivieren LOW PASS Regler zur Einstellung der Tiefpasstrennfrequenz von 35 Hz bis 200 Hz LEVEL Regler zur Anpassung der Eingangsempfindlichkeit der Mono Endstufe im Bereich von 0 2V bis 9V PHASE SHIFT Regler zur Einstellung der akustischen Phase des Subwoofer Ausgangs respektive Anpassung der absoluten Phase des ange schlossenen Subwoofers an die...

Страница 12: ...stärkers sollte auf eine ausreichende Kühlmöglichkeit durch Wärmekonvektion geachtet werden mind 5 cm Freiraum rund um das Gehäuse Die Kühlluft Zirkulation für den eingebauten Lüfter darf auf keinen Fall behindert werden Montageorte mit unbekanntem Hinter bzw Untergrund z B Kraftstofftank Kraftstoff und Bremsleitungen Bordelektronik etc sollten gemieden werden Das Bedienfeld zur Frequenzweichenein...

Страница 13: ...den Sie minde stens doppelt oder besser dreifach geschirmte Cinch Kabel Schliessen Sie das Remote Kabel an das mit Antenna Rem oder Amplifier Rem bezeichnete Kabel Ihres Steuergerätes an Anschliessend stecken Sie die Cinchkabel in die betreffenden Cinch Eingangsbuchsen des Verstärker ein Hinweise zu XP700 5 und XP800 1 Montieren Sie die SUB LEVEL CONTROL Fernbedienung in Griffnähe und schliessen S...

Страница 14: ...llitenkanäle ohne interne Umschaltung Zu diesem Zwecke schliessen sie die Lautsprecherkabel entspre chend an die Ausgangsterminals an Die gebrückten Kanäle sind jeweils 2 Ohm stabil die XP600 4 erlaubt somit den Betrieb eines Sat Sub Systemes mit den Kanälen 3 4 CH gebrückt und im Lowpass Betrieb für den Subwoofer Die XP700 5 erlaubt den gebrück ten Betrieb der Front und Rear Kanäle 1 2 CH 3 4 CH ...

Страница 15: ... und endet bei der eingestellten LOWPASS Frequenz LOW PASS Die sub sonischen Tiefbass Signalanteile meist unhörbarer Infraschall werden durch das SUBSONIC Filter entsprechend ausgeblendet Sämtliche Filter Elektroniken der XP600 4 XP700 5 und XP800 1 arbeiten mit einer Flankensteilheit von 12 dB Okt Vor Beginn der Einstellungsarbeiten an Ihrem X PULSE Verstärker müssen alle Klangregler am Steuerger...

Страница 16: ...einen dem Einsatzzweck der Belastbarkeit der verwendeten Lautsprecher und Ihrem Geschmack angepassten Kompromiss LEVEL Eingangsempfindlichkeits Anpassung Die korrekte Eingangsempfindlichkeits Anpas sung zwischen Steuergerät und Verstärker LEVEL ist wichtig für die Ausnutzung des opti malen Dynamikspielraumes Ihrer Steuergerät Verstärker Lautsprecherkombination Dieser Empfindlichkeitsabgleich beein...

Страница 17: ...en Sie den LEVEL Regler an Ihrem Ver stärker im Gegenuhrzeigersinn in die Minimum position 9V Drehen Sie den Regler der sepa raten Sub Level Fernbedienung voll auf Schal ten Sie Ihr Head Unit ein und stellen Sie den Lautstärkeregler auf ca 3 4 der Maximallaut stärke Verwenden Sie für die nun kommenden Einstellungen ein gut aufgenommenes dynami kreiches Musikstück Drehen Sie den LEVEL Regler der XP...

Страница 18: ... not lost in the form of unnecessary waste heat generation as encountered with all tradi tional analogue amplifier switching technolo gies In fact the minimised power wasting with digital amplifier switching technology is surely a desirable side effect as conventional ampli fiers also require a certain heatsink area that is usually increasing proportionally with the output power capacity of the am...

Страница 19: ... PULSE dealer installer in order to qualify for full warranty protection and to reach the maximum power and audio perfor mance possible with your individual automoti ve audio system Please check the set contents of your new X PULSE power amplifier carefully The original packaging should contain 1 XP600 4 XP700 5 XP800 1 Power Amplifier 1 Sub Level Remote Control Unit Interconnect Cable XP700 5 XP8...

Страница 20: ...CH 2 CH RCA Input Low level signal input sockets for connection with the line outputs of the head unit prefe rably the Front Line Outs or external electronic equalizers crossovers DSP black boxes etc 3 CH 4 CH RCA Input Low level signal input sockets for connection with the line outputs of the head unit prefe rably the Rear or Sub Line Outs or external electronic equalizers crosso vers DSP black b...

Страница 21: ...the setting of the desired subsonic highpass frequency between 10 Hz and 50 Hz The subsonic highpass filtering option is only active when the 3 4 CH X OVER switch is set to LOW PASS LOW HIGH PASS Highpass frequency control knob to adjust the integrated 12 dB oct highpass filter of channels 3 4 CH when the slide switch of 3 4 CH X OVER is set to HI highpass mode Allows the set ting of the required ...

Страница 22: ... overload LED is lit yellow when the subchannel is overdriven 1 CH 2 CH RCA INPUT Low level signal input sockets for connection with the line out puts of the head unit preferably the front line outs or external electronic equalizers cross overs DSP black boxes etc 3 CH 4 CH RCA INPUT Low level signal input sockets for connection with the line out puts of the head unit preferably the rear line outs...

Страница 23: ...channel Allows the setting of the desired highpass frequency between 10 Hz and 50 Hz The subsonic highpass filtering of the sub channel can not be defeated 5 CH SUB LEVEL Input gain adjustment knob to adjust match the input gain of the subwoofer channel to the incoming signal from the head unit The input level stage accepts input voltages between 0 2V to 9V 3 4 CH LEVEL Input gain adjustment knob ...

Страница 24: ... 10Hz 45 47 50Hz 140 90 50 35Hz 160 180 200Hz 0 6 1 4 3 8 9V 0 35 0 25 0 2V 3b 3a 4 5 1 6 7 8 9 SP SP 10a 10b 11 12 13 14 CONNECTIONS CONTROLS XP800 1 2a 2b Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 32 PM Seite 24 ...

Страница 25: ...can not be defeated LOW PASS Lowpass frequency control knob to adjust the integrated 12 dB oct lowpass filter Allows the setting of the required lowpass frequency bet ween 35 Hz and 200 Hz LEVEL Input gain adjustment knob to adjust the inco ming signal from the head unit between 0 2V to 9V PHASE SHIFT Phase shift knob to adjust the absolute phase of the amplified output signal Used to match the ph...

Страница 26: ... amplifier as shown in the explosion drawing using the sup plied Allen hex head wrench in order to access the four mounting holes on the four outside corners of the amplifer Use the amplifier as a template for the marking of the mounting holes on the selected moun ting surface with pencil or felt tip Pilot drill the mounting holes on the mounting surface using a 2 5 mm or 3 mm drill Mount the ampl...

Страница 27: ...sure to benefit from a perfectly noise free signal transmission Carefully run the RCA interconnect cables from the head unit to the amplifier To be on the safe side we recommend that the interconnects should be routed away from the power cables and any potential sources of electrical interfe rence e g electronic vehicle management systems engine computers relays etc fuel pumps wiring harnesses etc...

Страница 28: ...ed Allen wrench and the hex head screws MINIMUM IMPEDANCE LOAD OPTIONAL BRIDGED OPERATION MODE All three X PULSE amplifiers have been desi gned to operate at impedance loads as low as 1 ohm per channel Make sure that the total impedance load in bridged mode concerning XP600 4 and XP700 5 only will never be less than 2 ohms For connecting speakers in bridged mode please refer to the respective conn...

Страница 29: ...rnal electronic subsonic high pass lowpass crossover filtering circuitry separates the frequency spectrum from the signal inputs into highpass signals which exclude all frequencies below the selected point and lowpass signals which exclude all frequencies above the selected point The HIGHPASS signals for FRONT and REAR are then internally transferred to the respective satellite amplification secti...

Страница 30: ...rols for channel 1 2 CH and 3 4 CH The appropriate settings should be determined by ear The two most important factors for the individual adjustment will be the reproduction of the mid bass frequencies and the required safe power handling capacity of the satellites If the satellite cross over frequency is very low the mid bass reproduction will be increa sed but at the same time the safe power han...

Страница 31: ...nimum Now you set the volume control of your head unit to approximately 3 4 of full volume while playing a dynamic piece of music Turn up the separate Sub Level remote control unit to full volume Slowly turn up the LEVEL control knob on the amplifier until you can just about hear distor ted bass sounds Now you reduce the main volume level on the head unit to a medium listening level You can now pr...

Страница 32: ... 45 10Hz 50Hz SUBSONIC LEVEL 1 8 1 3 5 0 4 9V 0 2V 135 180 100 55 195 40Hz 200Hz HIGHPASS 135 180 100 55 195 40Hz 200Hz HIGHPASS 36 40 32 20 45 10Hz 50Hz HI FULL LOW HI FULL LOW 3 4CH X OVER 100 135 50 45 175 35Hz 200Hz LOWPASS SUBSONIC 1 8 1 3 5 0 4 9V 0 2V LEVEL 1 2CH X OVER 100 135 50 45 175 35Hz 200Hz LOWPASS 36 40 32 20 45 10Hz 50Hz SUBSONIC LEVEL 1 8 1 3 5 0 4 9V 0 2V 135 180 100 55 195 40Hz...

Страница 33: ...Hz LOWPASS 36 40 32 20 45 10Hz 50Hz SUBSONIC LEVEL 1 8 1 3 5 0 4 9V 0 2V 135 180 100 55 195 40Hz 200Hz HIGHPASS 135 180 100 55 195 40Hz 200Hz HIGHPASS 36 40 32 20 45 10Hz 50Hz HI FULL LOW Hi FULL LOW 3 4CH X OVER 100 135 50 45 175 35Hz 200Hz LOWPASS SUBSONIC 1 8 1 3 5 0 4 9V 0 2V LEVEL 1 2CH X OVER 100 135 50 45 175 35Hz 200Hz LOWPASS 36 40 32 20 45 10Hz 50Hz SUBSONIC LEVEL 1 8 1 3 5 0 4 9V 0 2V 1...

Страница 34: ...2V 135 180 100 55 195 40Hz 200Hz HIGHPASS 135 180 100 55 195 40Hz 200Hz HIGHPASS 36 40 32 20 45 10Hz 50Hz HI FULL LOW HI FULL LOW 3 4CH X OVER 100 135 50 45 175 35Hz 200Hz LOWPASS SUBSONIC 1 8 1 3 5 0 4 9V 0 2V LEVEL 1 2CH X OVER 100 135 50 45 175 35Hz 200Hz LOWPASS 36 40 32 20 45 10Hz 50Hz SUBSONIC LEVEL 1 8 1 3 5 0 4 9V 0 2V 135 180 100 55 195 40Hz 200Hz HIGHPASS 135 180 100 55 195 40Hz 200Hz HI...

Страница 35: ...177 35Hz 200Hz 38 45 32 20 48 10Hz 50Hz SUB 1 5 0 8 2 4 4 0 4 9V 0 2V 85 135 50 45 175 35Hz 200Hz 2 1 3 5 0 5 9V 0 2V INPUTMODE HI PASS 2CH 4CH 5CH 1 2CH X OVER 1 2CH LEVEL FRONT HP FULL HP BP 3 4CH X OVER HI PASS FULL 3 4CH LEVEL REAR PHASE SHIFT SUBSONIC 5CH LEVEL INPUTMODE LOW PASS 2 1 4 6 0 5 9V 0 2V LOW PASS 35 3 PRE OUT FRONT REAR SUB CD MD CHANGER HEAD UNIT SUB LEVEL CONTROL PASSIVE X OVER ...

Страница 36: ... 5 0 5 9V 0 2V XP700 5 5 CHANNEL AMPLIFIER INPUTMODE HI PASS 2CH 4CH 5CH 1 2CH X OVER 1 2CH LEVEL FRONT HP FULL HP BP 3 4CH X OVER HI PASS FULL 3 4CH LEVEL REAR PHASE SHIFT SUBSONIC 5CH LEVEL INPUTMODE LOW PASS 2 1 4 6 0 5 9V 0 2V LOW PASS 90 0 180 120 150 60 30 170 265 110 45 345 40Hz 400Hz 135 165 100 55 195 40Hz 200Hz 119 160 72 42 177 35Hz 200Hz 38 45 32 20 48 10Hz 50Hz SUB 1 5 0 8 2 4 4 0 4 9...

Страница 37: ...65 100 55 195 40Hz 200Hz 119 160 72 42 177 35Hz 200Hz 38 45 32 20 48 10Hz 50Hz SUB 1 5 0 8 2 4 4 0 4 9V 0 2V 85 135 50 45 175 35Hz 200Hz 2 1 3 5 0 5 9V 0 2V INPUTMODE HI PASS 2CH 4CH 5CH 1 2CH X OVER 1 2CH LEVEL FRONT HP FULL HP BP 3 4CH X OVER HI PASS FULL 3 4CH LEVEL REAR PHASE SHIFT SUBSONIC 5CH LEVEL INPUTMODE LOW PASS 2 1 4 6 0 5 9V 0 2V LOW PASS 37 3 PRE OUT FRONT REAR SUB CD MD CHANGER HEAD...

Страница 38: ...0 25 10Hz 45 47 50Hz 140 90 50 35Hz 160 180 200Hz 0 6 1 4 3 8 9V 0 35 0 25 0 2V SUBWOOFER CD CHANGER HEAD UNIT PRE OUT SUB XP800 1 SYSTEM CONFIGURATION Ne2 XP6004 7005 8001 RZ D UK 16 08 2000 6 33 PM Seite 38 ...

Страница 39: ...nce 47k 47kΩ 47kΩ Fan Yes Yes Yes LED Power Protect Power Protect Overload Power Protect Overload Protection DC Short Thermal Overload Yes Yes Yes Crossovers Phase Shift Phase Shift 0 180 No Yes But only 5CH Yes Crossover S W for 1 2 channel HP FULL LP HP FULL No Variable Hi Pass 40Hz 200Hz 40Hz 400Hz No Variable Low Pass 35Hz 200Hz No 35Hz 200Hz Subsonic Filter 10Hz 50Hz No 10Hz 50Hz Crossover S ...

Страница 40: ...er Serial No Modell Model XP6000 4 XP7000 5 XP8000 1 Adresse des Händlers Dealer s Address X Pulse Produkte werden entwickelt und hergestellt von X PULSE Schulze Delitsch Str 3 D 79761 Waldshut Tiengen Deutschland Exklusiv Vertrieb für alle X Pulse Produkte weltweit ACR Brändli Vögeli AG Bohrturmweg 1 CH 5330 Zurzach Schweiz Tel 41 0 56 269 64 64 Fax 41 0 56 269 64 65 GARANTIEKARTE GUARANTEE CARD ...

Отзывы: