Input Programming
There are (8) inputs, as well as a 24V DC and ground
bottom of the controller. On the ‘Run Tool’ scre
of the 8 inputs. When an input is active, the light will illuminate
setup. See the chart at the end of this section for pin location and other technical informati
instructions below detail how to set up various commands through the inputs.
•
TASK SELECT
: From the ‘Run Tool’ Screen:
o
Tap the ‘Setup’ Button
o
Make sure the task shown at the top is the one to be programmed.
o
Tap the ‘Inputs’ Button
o
Tap the arrow button on the
Tap the button on the left that
appear in the chart next to each input number. You may now select which input you want to
use to select the task by tapping the ‘Ignore’ button to the right of that input. This will toggle
between ‘H’,’L’, and ‘Ignore’ with each tap. The picture to the right of this button shows what
the controller is currently seeing on that input. Press t
changes if desired.
If the input requirements are not met
given bolt when the user tries to trigger the tool, the tool will not run and a banner messag
appear on the ‘Run Tool’ screen to notify the user that the input requirements are not met.
Note: after programming, the controller will switch to the task when that input is keyed,
and will stay there until commanded to switch tasks either via
controls. The input does not need to stay on for the task to remain enabled. If you desire the
input to be active in order for the task to run, we recommend you go to the next section and
setup each bolt in that task to req
Highlight
Page 20
, as well as a 24V DC and ground supply available through the input connector on the
On the ‘Run Tool’ screen, there is a row of lights at the bottom showing each
of the 8 inputs. When an input is active, the light will illuminate blue to aid in trouble-shooting and
See the chart at the end of this section for pin location and other technical informati
instructions below detail how to set up various commands through the inputs.
: From the ‘Run Tool’ Screen:
Tap the ‘Setup’ Button
Make sure the task shown at the top is the one to be programmed.
Tap the ‘Inputs’ Button
ton on the bottom next to ‘Setup Bolt(s)’ so that ‘Setup Misc’ appears.
ap the button on the left that shows the task name. You should now see a column of buttons
appear in the chart next to each input number. You may now select which input you want to
use to select the task by tapping the ‘Ignore’ button to the right of that input. This will toggle
between ‘H’,’L’, and ‘Ignore’ with each tap. The picture to the right of this button shows what
is currently seeing on that input. Press the yellow [<<] button at the top and save
If the input requirements are not met (signal from an external device is not present or lost)
given bolt when the user tries to trigger the tool, the tool will not run and a banner messag
screen to notify the user that the input requirements are not met.
: after programming, the controller will switch to the task when that input is keyed,
and will stay there until commanded to switch tasks either via the input or the touch screen
controls. The input does not need to stay on for the task to remain enabled. If you desire the
input to be active in order for the task to run, we recommend you go to the next section and
setup each bolt in that task to require the same input used for the task selection.
available through the input connector on the
en, there is a row of lights at the bottom showing each
shooting and
See the chart at the end of this section for pin location and other technical information. The
that ‘Setup Misc’ appears.
. You should now see a column of buttons
appear in the chart next to each input number. You may now select which input you want to
use to select the task by tapping the ‘Ignore’ button to the right of that input. This will toggle
between ‘H’,’L’, and ‘Ignore’ with each tap. The picture to the right of this button shows what
button at the top and save
(signal from an external device is not present or lost) for a
given bolt when the user tries to trigger the tool, the tool will not run and a banner message will
screen to notify the user that the input requirements are not met.
: after programming, the controller will switch to the task when that input is keyed,
the input or the touch screen
controls. The input does not need to stay on for the task to remain enabled. If you desire the
input to be active in order for the task to run, we recommend you go to the next section and
uire the same input used for the task selection.