Xiotech—Proprietary
160337-000 Rev D, 30 September, 2013
Page 5
Introduction
ISE User Guide
ISE Fibre Channel
The ISE has four Small Form-Factor Pluggable
+
(SFP
+
) Fibre Channel connectors per MRC, providing
maximum throughput with eight Gigabit host port connectivity. These Fibre Channel host ports connect hosts to
a Storage Area Network through Fibre Channel switches. Using multiple Fibre Channel switches for host
connections achieves fault tolerance at the storage-to-network interface. See “ISE Ports View” on page 21 and
“Direct Attach (DAS)” on page 21.
The ISE Fibre Channel ports operate in Old-Port mode and comply with the following specifications:
•
Fibre Channel Framing and Signaling (FC-FS)
, Revision 1.90
•
Fibre Channel Link Services (FC-LS)
, Revision 1.0 to
SCSI Primary Commands (SPC-3)
, Revision 22a
•
SCSI 3 Block Commands (SBC)
, Revision 8C
•
SCSI Architecture Model 3 (SAM-3)
, Revision 13 of the SCSI specifications
Extremely high drive operability is provided by the ISE Managed Reliability feature, which corrects many drive
failures without operator intervention. A data migration utility is available through
X-IO
Customer Support if an
entire DataPac requires replacing. Capacity for hot sparing is automatically provided within the DataPac and
managed by the MRCs.
The ISE has two Ethernet management ports, one on each MRC, and can operate in either Dynamic Host
Configuration Protocol (DHCP) mode or static IP mode. DHCP mode is enabled by default at the factory.
Three easy-to-use management interfaces provide configuration and control of the ISE:
•
Orchestrator—an advanced Web based interface facilitating the management of all ISE systems within an
Ethernet network as documented in the
Orchestrator User Guide
•
Classic Management Interface—a Web-based management interface, accessible from a browser
anywhere on the network
•
Command Line Interface (CLI), accessible from a remote console anywhere on the network
See “Web Management Interface” on page 27 and “Characters—Web-Mgt and CLI” on page 29 for a detailed
description of these interfaces.
TMRA
The TMRA (Temperature-Maximum Recommended Ambient) is 40° C.
La Temperatura-máxima recomendada ambiente (TMRA) es de 40 grados C.
Die
T
mra (empfohlene maximale Umgebungstemperatur für den Betrieb) liegt bei 40° C.
A TMRA (temperatura ambiente máxima de funcionamento recomendada) é de 40° C.
Максимально
допустимая
температура
окружающей
среды
составляет
40°C.
General Hazards
Elevated Operating Ambient Temperature
When installed in a closed or multi-unit rack assembly, the operating ambient temperature within the rack may
exceed the room ambient temperature. Consideration should be given to installing the equipment in an
environment compatible with the manufacturer’s maximum recommended ambient temperature (TMRA).
Содержание ISE-2 Series
Страница 1: ......
Страница 8: ...Page vi 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Table of Contents...
Страница 36: ...Page 28 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Installation...
Страница 44: ...Page 36 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Management Tools...
Страница 74: ...Page 66 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Initialize and Configure...
Страница 108: ...Page 100 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide ISE Management...
Страница 132: ...Page 124 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Monitoring...
Страница 154: ...Page 146 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Maintenance...
Страница 158: ...Page 150 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide FRU Replacement...
Страница 166: ...Page 158 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Appendix B Troubleshooting...
Страница 174: ...Page 166 160337 000 Rev D 30 September 2013 Xiotech Proprietary ISE User Guide Appendix C CLI Commands...
Страница 178: ......