Wiring and Connections

WyreStorm recommends that all wiring for the installation is run and terminated prior to making connections to the switcher.  Read through this section in this 
entirety before running or terminating the wires to ensure proper operation and to avoid damaging equipment.

  IMPORTANT! Wiring Guidelines

 

• 

The use of patch panels, wall plates, cable extenders, kinks in cables, and 

electrical or environmental interference will have an adverse effect on 

signal transmission which may limit performance.  Steps should be taken 
to minimize or remove these factors completely during installation for best 

results

• 

WyreStorm recommends using pre-terminated HDMI and DP cables due to 
the complexity of these connector types.  Using pre-terminated cables will 

ensure that these connections are accurate and will not interfere with the 
performance of the product.

HDMI Cable 

Pe

rformance Guide

4K 

Transmission

HD 

Transmission

0ft

98ft

10ft

20ft

30ft

39ft

49ft

59ft

69ft

79ft

89ft

0m

30m

3m

6m

9m

12m

15m

18m

21m

24m

27m

  IMPORTANT! IR TX/RX Guidelines

 

• 

Using WyreStorm infrared emitters and receivers is the best way to 
ensure that most IR coding formats are transmitted and received by 
the NetworkHD system. Other 3rd party emitters and receivers can be 

used; however, these devices must operate in the same manner as the 

WyreStorm devices.

• 

On the 100/200/400 series the IR data modulation (carrier) frequency is 
passed through NetworkHD from the receiver to the emitter, however on 
the 600 series the carrier frequency is fixed at 38kHz when used in pass-
through mode. When using the API the carrier frequency can be defined for 
greater compatibility.

• 

Due to differences in IR across 3rd party control systems their IR ports 
should never be connected directly to a NetworkHD system as an 
incompatibility may exist. WyreStorm offers a cable that compensates for 

voltage differences as well adjusts for differences in the pins used within 

the port. Refer to the 

CAB-IR-LINK

 product page for more information.

IR TX Port Pinout

Connection for IR TX (transmit) uses a 3.5mm (1/8in) mono plug.

IR RX Port Pinout

Connection for IR RX (receive) uses a 3.5mm (1/8in) stereo jack that outputs 
+5V DC to power the included IR receiver. 

SDVoE Wiring

The NetworkHD 600 Series utilize a 10GbE link connection to a
10GBASE-T Ethernet switch port. Please refer to IEEE 802.3an for
official guidance on the Ethernet link. Cables must be tested to 500MHz
across the entire link.
10GBASE-T uses the IEC 60603-7 8P8C modular connector.

LAN Port Wiring

The NetworkHD 600 Series LAN port is a 1GbE link for
connection to a 1000BASE-T Ethernet device port. Please refer to IEEE
802.3ab for official guidance on the Ethernet link. Cables must be tested
to 100MHz across the entire link.
1000BASE-T uses the IEC 60603-7 8P8C modular connector.

RS-232 Wiring

The NetworkHD 600 Series uses 3-pin RS-232 with no hardware flow control.  
Most control systems and computers are DTE where pin 2 is RX, this can vary 
from device to device.  Refer to the documentation for the connected device 
for pin functionally to ensure that the correct connections can be made.

Audio Wiring

The audio connections use a 3.5mm (1/8in) TRS Stereo Jack.