Nexera LX User Manual
Updated March 2009
Page 5
•
Protection against electric shock is assured only if the mains connected cord set is
connected to a properly earthed grounding type receptacle.
•
Disconnect the fixture from AC power before removing or installing the lamp, fuses, or
any electronic parts.
•
Use a good source of AC power that complies with local building and electrical codes
and has both overload and ground fault protection.
•
Suitable for dry locations only. Do not expose the fixture or power supply to rain or
moisture.
•
Refer all service to a Wybron certified service technician.
To protect yourself and others from burns and fire:
•
Maximum ambient temperature Ta=40º C (104º F).
•
DANGER: INTENSE HEAT. AVOID CONTACT BY PERSONS AND MATERIALS.
•
For continued protection against risk of fire, replace only with same type and rating of
fuse. Do not operate the fixture with missing or damaged lenses or reflector.
•
Replace any cracked protective shield.
•
When replacing the lamp, allow the fixture to cool for at least five minutes before
removing the lamp holder from the fixture.
•
Do not stare directly into the light. Never look at an exposed lamp while it is
illuminated.
•
Replace the lamp if it becomes damaged or thermally deformed.
•
A hot lamp may be an explosion hazard. Do not open the fixture for five minutes after
power has been disconnected. Wear eye and hand protection when re-lamping.
•
Do not use any lamps other than those approved for use by Wybron and listed in this
manual. Use of any other lamp may be hazardous and may void the warranty.
•
Minimum distance to lighted objects: 1 meter (3.28 feet).
•
Minimum distance to flammable objects (fabric, wood, paper, etc): 1 meter (3.28 feet).
•
Nexera LX fixtures are convection cooled. Provide a minimum clearance of 0.1 meter
(4 inches) around all air vents.
•
Do not modify the fixture or install any parts other than genuine Wybron replacement
parts.
FOR TUNGSTEN UNITS (Models 2560, 2570, 2640):
•
Maximum exterior surface temperature Tmax=180ºC (356ºF). Allow the fixture to
cool before handling.
•
IP20.
FOR CDM UNITS (Models 2580, 2600):
•
Maximum exterior surface temperature Tmax=90ºC (194ºF).
•
IP20.
•
CAUTION: Risk of exposure to excessive ultraviolet (UV) radiation. Do not
operate without complete lamp enclosure in place.
To protect yourself and others from injury due to falls:
•
When suspending the fixture above ground level, verify that the structure can hold
at least 10 times the weight of all installed devices.
------1m