CAUTION
Attaching Accessories to the Front Holder
Nexera LX can accept up to two standard
accessories (7.5” for the wash, 6.25” for the
profile). Accessories are safely held in place
with a standard spring-loaded latch.
From the front of the fixture, push the
accessory retaining latch to the right.
After the latch locking pin clears, move the
latch up.
Load the accessory then push the latch to
the right and down to hold the accessory
in place. The spring will engage the
locking pin in the fixture.
Connecting AC Power
Be sure the fixture is properly grounded. Don’t touch
the sparking parts.
Use a good source of AC power that complies with local building and electrical
codes and has both overload and ground fault protection. If the Nexera LX
fixture was received without an AC lamp cord plug attached, attach the
appropriate lamp cord plug according to the following code:
Tungsten units (Model 2560, 2570, 2640, 2650) CDM units (Model 2580, 2600)
green and yellow – ground/earth
tan – neutral
tan – line
Be sure that the AC power source is appropriate for the lamp being used.
Adjusting Field Angle
Field angle can be adjusted on the Nexera LX
wash light.
Loosen the Fresnel adjustment knob.
Move the Fresnel back to increase field
angle, or forward to reduce the field angle.
Tighten the Fresnel adjustment knob to
secure desired field angle.
Retaining
latch
Accessory
holder
Fresnel
adjustment
knob
green and yellow – ground/earth
blue – neutral
brown - line