background image

19

Follow these steps to install the hanger bracket.

1. Disconnect AC power from the power supply.

2. Place the power supply on its side on a flat surface.

3. Position the brackets as shown below.

4. Attach the bracket using a 3/16" Allen wrench and the supplied screws.

Note: Use the supplied thumb screws to clamp the hanger brackets to the desired pipe 
or truss.

Figure 6

9

0

 

-

 2

5

0

 V

A

C

 5

0

 

/

 6

0

 H

Z

4

 A

M

P

 S

L

O

-

B

L

O

 A

T

 1

1

5

 V

A

C

2

 A

M

P

 S

L

O

-

B

L

O

 A

T

 2

3

0

 V

A

C

12

 W

A Y

 P

O

WE

R

 S

U

PP

LY

19

01

2

Figure 10

Содержание Coloram II 19000

Страница 1: ...Power Supply User Manual...

Страница 2: ...tion 4 The Coloram II System 4 The Coloram II System Components 5 Color Changers and Other Components 5 Power Supply 6 Cables 6 The Coloram II Power Supply Menu 7 Menu Tree 7 Menu Details 7 Error Mess...

Страница 3: ...es step by step instructions for preparation setup and operation of the Coloram II Power Supply There is a potential risk of fire electric shock or injury to persons if the product is not used as inst...

Страница 4: ...oard is connected to the power supply and can continue on to more Coloram II Power Supplies or other DMX controlled devices The power supply sends both power and control signal on a single cable elimi...

Страница 5: ...System Components Color changers and other components The color changers set the position of the gelstring via a signal from the lighting console The control signal and DC power 24 VDC are both suppli...

Страница 6: ...color changer status Coloram II Cable The Coloram II Cable connects the Coloram II Power Supply outputs to the Coloram II Color Changers or other products and provides them with power and control sig...

Страница 7: ...00 DCV 24 Fan NORM Mtr NORM Ver x x CXI IDENTIFY DCV 24 Fan NORM Ver x x OR GLA 0 GLB 0 MEANS PRESS MEANS PRESS BUTTON BUTTON ALERT DETAILS APPEAR HERE X ALERT POWER UP SCREENS RUN SCREEN LOOP Menu De...

Страница 8: ...d gel position and the actual gel position VDC xxx Color changer voltage is below 17 volts DC Shut xxx Color changer reports a SHUTDOWN condition will not respond to position commands because the volt...

Страница 9: ...t more information on the alerts 4 As an example Pstn 001 indicates the head unit 1 has a position error 5 Press Enter to get information on other alerts 6 Viewing the alerts in this manner also clear...

Страница 10: ...t to normal or low Enter Ver x x This tells you the software version installed in the color changer set to the channel you are looking at Enter Identify Pressing will cause the color changer whose sta...

Страница 11: ...nger is rotating the carriers toward FL an arrow pointing to the right will be displayed If the gobo changer is rotating the carriers toward 00 an arrow pointing to the left will be displayed Enter Sp...

Страница 12: ...is option turns talkback to a remote status monitor on or off Status of the color changers or gobo changers will still be displayed in the status menu If this is turned on the first channel of the pow...

Страница 13: ...the option Pressing and will increment and decrement numbers or toggle options Pressing Enter will confirm your selection and the question mark will go away Disp This option allows you to select how...

Страница 14: ...options will bring up a question mark behind the option Pressing and will increment and decrement numbers or toggle options Pressing Enter will confirm your selection and the question mark will go aw...

Страница 15: ...h a mounting bracket which hooks over the pipe or truss of your lighting rig and is then locked into place with a thumb screw If you have selected this mounting method connect the power supply s safet...

Страница 16: ...the software version installed in it The power supply will then initiate a roll call which tells the color changers to check in and initialize the gel string Caution Do not power the power supply fro...

Страница 17: ...to the DMX signal until you return in the menu tree to the RUN SCREEN loop 5 Connect and set the DMX512 source Connect the DMX512 signal source to the DMX input connector on the front of the power su...

Страница 18: ...orams is 20 feet long The amount of cable from the power supply to 1st Coloram II 100 ft 2nd Coloram II 120 ft 3rd Coloram II 140 ft 4th Coloram II 160 ft total 520 Head Feet Mounting and installation...

Страница 19: ...flat surface 3 Position the brackets as shown below 4 Attach the bracket using a 3 16 Allen wrench and the supplied screws Note Use the supplied thumb screws to clamp the hanger brackets to the desire...

Страница 20: ...install the power supply into the rack mounting tray 1 Disconnect AC power from the power supply 2 Place the rack mount tray right side up on a flat surface 3 Position the power supply in the rack mo...

Страница 21: ...first 24 channels 2 CXIs use 1 2 or 3 channels 3 Colorams use 1 channel 4 Eclipses use 1 channel 5 Goboram IIs use 3 channels Cables Coloram II Cable The Coloram II Cable uses 4 pin XLR connectors on...

Страница 22: ...upply model 19000 7 amp slo blo at 115 VAC 4 amp slo blo at 230 VAC 12 Way Power Supply model 19012 4 amp slo blo at 115 VAC 2 amp slo blo at 230 VAC 6 Way Power Supply model 19060 2 amp slo blo at 11...

Страница 23: ...el shown will be the last channel used by the power supply for talkback 5 In the CRI mode the power supply can control more color changers on separate channels 6 Increased the highest starting channel...

Страница 24: ...3 power signal cable 7042 5 5 power signal cable 7042 10 10 power signal cable 7042 15 15 power signal cable 7042 25 25 power signal cable 7042 50 50 power signal cable 7042 75 75 power signal cable 7...

Страница 25: ...or any incidental general or consequential damages to property damages for loss of use time profits or income or any other charges The owner s obligations during the warranty period under this warrant...