20
3. - Periods
Periods
Caution
Menu “3. Times” is used to set the time, date, operating times for e.g. the heating
circuit and hot water.
The menu is closed by pressing “esc” or selecting “Exit periods”.
The associated temperature reference values are speci
fi
ed in menu 5 “Set-
tings”!
3.1. - Heating circuit day
This menu is used to select the daytime mode times for the heating circuit; three time periods can be speci
fi
ed for each weekday
and copied to other days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su 6:00-22:00
Note: See 5. for the associated temperature settings
Caution
Times that are not speci
fi
ed are automatically considered to be nighttime mode. The set times are only taken
into account in the heating circuit operating mode “Automatic”
3.2. - Heating circuit 2 day
This menu is used to select the daytime mode times for the second heating circuit; three time periods can be speci
fi
ed for each
weekday and copied to other days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su 6:00-22:00
Note: See 5. for the associated temperature settings
Caution
Times that are not speci
fi
ed are automatically considered to be nighttime mode. The set times are only taken
into account in the heating circuit operating mode “Automatic”
3.3. - Heating comfort
This menu can be used to select a time range for each day of the week in which the heating circuit is supplied with an in-
creased comfort temperature, e.g. for quick heating in the morning.
Setting range: One time range for each day of the week
Default: Mo-Su off
Note: See 5. for the associated temperature settings.
3.4. - Heating circuit 2 comfort
This menu can be used to select a time range for each day of the week in which the second heating circuit is supplied with an
increased comfort temperature, e.g. for quick heating in the morning.
Setting range: One time range for each day of the week
Default: Mo-Su off
Note: See 5. for the associated temperature settings.
Caution
Times that are not speci
fi
ed are set to “disabled”.
3.5. - Hot water enable
This menu is used to select the times when the domestic hot water heating is enabled (sensor 3); three time periods can be
speci
fi
ed for each weekday and copied over to the following days.
Setting range: Three time ranges for each day of the week
Default: Mo-Su 6:00-22:00
Note: See 11. for the associated temperature settings