If the batteries in a radio energy-saving controller have
been replaced, it can take up to 1½ hours until the
actuator starts to receive data from the wall thermostat
again and switches to “ECF” mode.
13. TEAcHINg-IN TO THE WALL THERMOSTAT
Up to 5 system components such as remote controls,
window contacts can be taught-in to the wall thermostat.
• To do this, press and hold down the OK button for longer
than 3 seconds.
• “LEA” and the remaining teach-in time (30 seconds)
appear on the display.
• The device to be taught-in now needs to transmit a radio sig
-
nal (by pressing a button on a remote control, for example).
• Once teaching-in has been completed successfully, a code
for the taught-in device appears on the wall thermostat’s
display for 3 seconds: rC – remote control, SC – window
contact.
• The display then returns to the standard view.
If 5 devices have already been taught-in to the wall
thermostat, “Err” appears on the display. In this case, one
of the taught-in devices needs to be taught-out before a
new device can be taught-in (see section 14).
14. TEAcHINg OUT WIRELESS cOMpONENTS
Components that have been taught in on the actuator can be
taught out again using the “UnL” (Unlearn) function. All wire
-
less components are taught out at once with this function.
• Press and hold down the mode button for more than 3
seconds.
• Use the setting wheel to select the “UnL” menu item.