23
Changing parameters
■
Select the desired parameter with button
[20]
(corresponding LEDs flash, see table)
■
Set the value with rotary knob
[13]
.
■
Confirm the new value with button
[20]
(the LEDs flash briefly).
The Annex to this manual contains templates to
simplify the setting of the ancillary parameters.
As a general rule, the default value of an ancillary
parameter corresponds to the middle position
(12 o'clock position) of the rotary knob
[13]
.
■
Switch off the machine and wait until all LEDs
have gone out.
■
Switch on the machine again. The new param-
eters are active.
Resetting to factory settings
■
Activating programming mode
■
Hold button
[20]
depressed until all the LEDs
flash a second time. All the ancillary parameters
are now reset to their default values.
■
Switch off the machine and wait until all LEDs
have gone out.
■
Switch on the machine again. The new param-
eters are active.
Current path
4-cycle
Secondary current
Starting current
Final current
Trigger current
Torch button 1
Gas
pre-flow
Torch button 2
Up slope
Down slope
Gas post-flow
Actuated
Actuated
Act.
Main current
2-cycle
Secondary current
min. current
Trigger current
Torch button 1
Gas pre-flow
Torch button 2
Up slope
Down slope
Gas post-flow
Actuated
Act.
Main current
Form of the electrode tip
Tungsten electrodes must always be welded in
longitudinal direction, as grinding scores running
transversely result in an unsteady electric arc.
The top of the electrode for DC welding must be and
remain pointed like a pencil.
The tip angle here depends on the welding current
strength.
Welding current [A] Electrode angle
20
30°
20 - 100
60 - 90°
100 - 200
90 - 120°
> 200
120°