WURM FKE003 Скачать руководство пользователя страница 4

FKE003

 

 
 

Product information 

 

Page 4 of 8 

Subject to technical changes 

FKE003_V2.2_PI_2018-01_EN 

 

WARNING! 

Danger to life from electric shock and/or fire! 

 

Switch power off to the entire system when installing and wiring! Otherwise a mains 
voltage and/or external voltage may still be present even if the control voltage is switched 
off! 

 
All connections are designed as plugs for prefabricated cable. 

 

Connections for prefabricated cables 

 
The following cables, CAN bus adapters and terminating resistors are available for the FKE003. 

Cables 

Application 

ZCB-C/TR-0.6 

Controller – transformer, 0.6m 

ZCB-C/TR-2.0 

Controller – transformer, 2.0m 

ZCB-C/REL2M-5P 

Controller – load, 5-pin 

ZCB-C/DI-2.0 

Controller - digital inputs, 2.0m 

ZCB-C/DI-7.0 

Controller - digital inputs, 7.0m 

ZCB-C/AI-2.0 

Controller (plug) – analogue input (wire end sleeves), 4…20mA, 2.0m 

ZCB-C/AI-7.0 

Controller (plug) – analogue output (wire end sleeves), 4…20mA, 7.0m 

ZCB-C/AO-2.0 

Controller (plug) – analogue output (wire end sleeves), 0…10V, 2.0m 

ZCB-C/BUS-0.6 

Controller – controller/bus adapter (plug), 0.6m 

ZCB-C/BUS-4.5 

Controller – controller/bus adapter (plug), 4.5m 

Bus adapter 

Application 

ZCB-ADP/BUS 

CAN bus adapter 

Terminating 
resistor 

Application 

ZCB-ADP/R 

Terminating resistor for CAN bus 

 
 
 
 

Содержание FKE003

Страница 1: ...ctronic relay valve controller 230V or ATV230 valve actuation 230V Control of one evaporator per module Integrated temperature display Tool free front installation Fixed input output allocation for se...

Страница 2: ...ric shock and or fire Switch off the power to the entire plant when installing wiring or removing Otherwise a mains voltage and or external voltage may still be present even if the control voltage is...

Страница 3: ...rol elements 5 4 Device operation 5 4 1 Activating the advanced level 5 4 2 Selecting parameters 5 4 3 Set parameter 6 4 4 Set module number 6 4 5 Block keys against unauthorised operation 6 5 Paramet...

Страница 4: ...for the FKE003 Cables Application ZCB C TR 0 6 Controller transformer 0 6m ZCB C TR 2 0 Controller transformer 2 0m ZCB C REL2M 5P Controller load 5 pin ZCB C DI 2 0 Controller digital inputs 2 0m ZC...

Страница 5: ...Advanced level will flash for as long as the level is released P P 5s 2 To return to the advanced level press the P key again for 5 seconds If no key is pressed within 2 minutes the display automatic...

Страница 6: ...ed within 2 minutes the display automatically returns to the standard level and parameter change is disabled The jump back is always made to the temperature display 4 4 Set module number For easier se...

Страница 7: ...ure of suction gas sensor S4 P05 Actual value 4 20mA 0 25 5 Current on 4 20mA input resolution 0 25 5mA P06 Actual value 0 10V output 0 100 Triggering of the 0 10V output resolution 0 100 P07 Sensor t...

Страница 8: ...d connection supply air return air defrost limit 1 x TRK EEV 7ST suction gas Analogue input 4 20mA output voltage 18V max 22mA Digital inputs 3 x potential free contact 1 x cold location off 1 x 2nd s...

Отзывы: