Cold location controller for top-hat rail installation with enhanced operating modes for 4 cold locations
CRC-BL_V2.4.0_PI_2021-02_DE
1
Subject to technical changes
CRC-BL
1 CRC-BL
Cold location controller for top-hat rail installation with enhanced operating modes for 4
cold locations
1.1
Front view
Fig. 1: Front view
1.2
Features
•
Suitable for 4 cold locations max.
•
Basic functional sequences and parameters preprogrammed by selection of cold location type
•
Intelligent fan control, compressor oscillation protection, fan delay
•
Thermal fan control and draining time after defrosting
•
Suitable for electric defrost, forced air defrost, hot gas defrost and cool gas defrost
•
Defrost control by real-time clock with power reserve
•
Simple defrost synchronisation of multiple controllers (master-slave)
•
8 defrost times by integrated weekly timer
•
Digital inputs for setpoint switchover, manual defrost initiation and door contact
•
Option to select 3-point control
•
Control sensor weighting can be set separately for day operation and night operation
•
Support for higher baud rates on the Wurm CAN communication bus (C-BUS)
•
Can be locked to prevent unwanted parameter adjustment (SAC - Security Access Control)
•
Plain text name for each parameter on the display, language selectable
•
Unique parameter identification with Quicklinks
•
BLUELINE operation
•
Plug-in screw terminals
•
Large data memory for temperature list
•
Connection to the Wurm system via C-BUS and FRIGODATA XP