12
6. Installation and commissioning
6.1. Assembly / installation
Vibrating motors can be installed in any installation position. They may only be
attached to machines with flat, oil, grease and paint-free and rigid mounting
surfaces.
Surface quality:
Only screws of quality class ≥ 8.8 ISO 4014 (DIN 931) or ISO 4017 (DIN 933) and
nuts of qu
ality class ≥ 8.8 ISO 4032 (DIN 934) may be used.
They must be secured against mechanical loosening by Schnorr washers or
similar.
The fastening screws must be checked for tightness after
approx. Two hours of operation and tightened if necessary.
Further checks should be carried out daily!
Tightening torques for fastening screws:
M5
M8
M10
M12
M16
M20
M22
M24
M27
M30
M36
8
Nm
30
Nm
55
Nm
90
Nm
150
Nm
280
Nm
370
Nm
450
Nm
1100
Nm
1350
Nm
2500
Nm
Always tighten the fastening screws crosswise.
For elongated holes (e.g. HV 0.4, HV 1, HV 2 and HV 6), ISO 7089 (DIN 125)
washers must also be used.
Содержание 2MV Series
Страница 26: ...26 HV 0 4 ...
Страница 27: ...27 HV 1 ...
Страница 28: ...28 HV 2 HF 2 ...
Страница 29: ...29 HV 6 HF 6 ...
Страница 30: ...30 HV 8 HV 30 ...
Страница 31: ...31 HV 8 HV 30 ...
Страница 32: ...32 HV 55 ...
Страница 33: ...33 HV 65 ...
Страница 34: ...34 HV 85 ...
Страница 35: ...35 HV 40 HV 200 ...
Страница 42: ...42 Notes ...
Страница 43: ...43 Notes ...