The PC software for the instrument 

 

Installation

 

of Windows software 

Software is designed for computer with operational system Windows, version Windows 95 or 

newer. There is approximately 5MB free space required on the hard disk. A free serial port is 
required for communication with the instrument. 

Start the installation from Control Panel of Windows (Start - Settings - Control panel) - 

Add/Remove programs, button Install. You will be suggested by Windows to insert first installation 
diskette. After pressing Next button installation of software for COMMETER will start.  

After installator start a window with License agreement occurs. Read the license agreement 

carefully please. All text is possible to view by cursor movement keys up and down or PageUp, 
PageDown keys. If you agree with the License agreement, press the Yes button. If you do not agree, 
press No and installation will be cancelled. 

In next step of installation it is possible to select path, where software will be install to. If you 

agree with offered path, press Next, otherwise change the path by button Browse. 

In the next window you can select folder in Start menu where software will be enable to run 

from. If you agree with offered folder, press Next.  

Now installation itself of software to hard disk will be carried out. Wait please for installator to 

perform all necessary steps. During installation you will be invited to insert second diskette. 

In the end message of successful installation will occur.  Quit the Installator by button Cancel. 

Now it is possible to run software from menu Start - Programs - Comet - CommDx. 

 

 
 

Software for Windows - instruction manual 
 
Communication with the instrument
  
 

First connect communication cable to computer serial port. Plug second connector of 

communication cable to the instrument and start data transfer to the computer (selection from menu 
File - from datalogger, key F4 or button on the toolbar). Software will find connection with the 
instrument and transfer data. Computer offers name of the file with measurement to be created on 
disk. Implicitly  files are stored to files with extension *.msb. File name is generated from year, 
month and day of file creation and  serial number in the day of creation. It is possible to use 
different file name and path. After name confirmation it is possible to insert short description with 
e.g. conditions or location of measurement which is stored together with measured values.  

 
 

Viewing of measured values 

Measured values can be read directly from datalogger or from formerly created file on disk 

(command File - From disk, key F3). After reading a table of measured values occurs. Detailed 
information on file is available from context menu - menu occurs after clicking right mouse button 
on the position of table. In context menu function export to text or database format is available. 

Graph with measured curves it is possible to by command Display - Graph or button on the 

toolbar. Graph mode enables to modify setting of axis, color of curves etc. Detailed information on 
software functions is available in help. 

 

10 

 

  IE-COM-D3120-01 

Содержание COMMETER D3120

Страница 1: ...COMMETER D3120 Digital thermometer hygrometer and datalogger Instruction manual ...

Страница 2: ...tic logging mode 10 s to 24 h Memory capacity for manual logging 1000 sets of all input quantities for non cyclic automatic logging total 8124 values for cyclic automatic logging total 7644 values The above specified numbers are are maximum possible Capacity is slightly lower if logging was interrupted by communication with computer by stopping logging or switching OFF the instrument Communication...

Страница 3: ...ains failure Switching ON and OFF the instrument Switch ON the instrument by pressing ON OFF key After switching ON the instrument all symbols on the LCD are displayed If the ON OFF key is being held pressed all LCD symbols are displayed till the key is released In usual operation instrument then starts the measurement mode and actual measured values are displayed If a voltage drop below critical ...

Страница 4: ...ode to display minimum resp maximum reading These minimum and maximum readings are indicated by MIN MAX symbols on the LCD Press DISPLAY key to display minimum resp maximum value of other values Pressing MIN MAX or MENU key again to return to default mode Minimum and maximum memory is cleared from menu after confirmation selection CLR see below Values in HOLD MIN and MAX memories remain stored eve...

Страница 5: ... indicated In the FAST mode refreshment is fastest with regular interval approximately 0 7 s In the dynamic refresh mode DYN each 15 s refresh interval of display is doubled to maximum 5 s if measured values are stable If measured values change refresh interval decreases to approximately 0 7 s This dynamic mode prolongs battery life significantly Select the desired mode by ENTER key Notice if batt...

Страница 6: ...Press and hold the arrow key UP to make value increase fast Press and hold the arrow key DOWN to make value decrease fast Release the arrow key and press ENTER to confirm new limit Reading ALHI indicates adjusted upper limit of the same alarm here air temperature Set the desired value in the same way as in above lower limit If needed it is possible to get back to lower limit setting of the same al...

Страница 7: ... when after fulfilling the memory oldest data are replaced with new values manual logging designed for manual storing of measured values by ENTER key Logging modes are not mutually compatible and after changing logging mode memory of the instrument should be cleared Logging in progress will always be interrupted by instrument connection to the computer or switching OFF the instrument by ON OFF key...

Страница 8: ... Clearing procedure is in progress It takes approximately 16 s and the duration is indicated by displaying of already cleared memory in digits 0 to 100 After memory is cleared it is possible to select one of three logging modes MODE by using arrow keys non cyclic logging is indicated by symbol n CYC cyclic logging by symbol CYCL and manual logging by symbol Man If manual logging mode is selected a...

Страница 9: ...ication including logging stop The most power from the battery is needed during communication with the PC let the communication cable plugged in the instrument only for time necessary for data transfer If you let instrument plugged in the computer longer than approximately 5 minutes with no communication instrument will be automatically switched OFF Battery replacement If battery voltage is low lo...

Страница 10: ...e of successful installation will occur Quit the Installator by button Cancel Now it is possible to run software from menu Start Programs Comet CommDx Software for Windows instruction manual Communication with the instrument First connect communication cable to computer serial port Plug second connector of communication cable to the instrument and start data transfer to the computer selection from...

Страница 11: ...red values it is possible to view those segments one by one Previous segment moves to previous segment Next segment moves next segment Curve setting color modification vertical axis assignment Graph setting setting of graph parameters axis description etc Graph channels one by one enables disables displaying of curves one by one i e there is only one curve on the screen at a time Graph channel nam...

Отзывы: