the transformer.

Warning: Connecting the CM49 to the wrong AC voltage may 
destroy the unit and cause fire and/or electric shock.

Replacing Fuses

The fuse protecting the primary circuit is located outside the PSU. 
Unscrew the black fuse cover to open the fuse compartment. 
Replace the fuse with a new fuse of the same type (T 500 mA for 
115V; 250 mA for 230V)

 

 and close the fuse compartment lid.

 

AC Power Connector

If you are using the microphone in a different country, you may 
need to connect the unit to a power outlet that does not match the 
power connector on the supplied power cable. Purchase a matching 
power cable locally that complies with IEC and local safety 
standards and has a power connector with a chassis ground pin. 
While in the same area, use this “local“ power cable only.

Shutdown and storage

Before switching off the microphone or disconnecting cables, reduce 
the volume of the connected equipment. Only then should the PSU 
be switched off.

Disconnect the cables. When disconnecting a cable, always pull only 
on the connector housing and not the cable itself.

When the microphone is not in use, it should not be allowed to 
remain on the stand gathering dust.

A microphone which is unused for a prolonged period should be 
stored in a cool, dry place and protected from dust.

 

Содержание CM49

Страница 1: ...would be advisable for the user to keep a spare tube specially selected by the Wunder Audio Service Department always ready for replacement It is important to note that the tube may have become slightly unplugged from the tube socket during shipping If the microphone has no audio output 99 of the time it is a result of a slightly unplugged tube Repairs are to be carried out only by experienced aut...

Страница 2: ... microphone A special Yoke mount stand adapter is provided and should always be used to mount the microphone on floor stands or booms To mount the microphone fully unscrew the knurled knob on the side of the metal belt Place the microphone into the metal belt making sure that the red jewel on the front of the microphone is centered into the center hole on the yoke belt Make sure that the there is ...

Страница 3: ... recommended The CM49 s tube will break in over a period of time enabling the mic to sound subtly better over a period of time 2 The CM49 Power Supply This PSU supplies the microphone with the 4 0V filament voltage and 120V plate voltage for the vacuum tube Prior to connecting the CM49 to AC power check the AC voltage of the power line you are going to connect to the CM49 The CM49 PSU has an inter...

Страница 4: ...e power connector on the supplied power cable Purchase a matching power cable locally that complies with IEC and local safety standards and has a power connector with a chassis ground pin While in the same area use this local power cable only Shutdown and storage Before switching off the microphone or disconnecting cables reduce the volume of the connected equipment Only then should the PSU be swi...

Страница 5: ... Possible causes a PSU not switched on b Microphone is not connected to PSU 2 Signal is noisy Possible causes a Tube filament has become damaged 3 Specifications of the Microphone Directional Characteristics Omni cardioid figure eight and eight intermediate positions remotely controlled from the microphone on the powering unit Frequency Range 20 20 000 Hz Electrical Impedance 200 ohms Powering Via...

Страница 6: ... to 0 6 at 100 dyne cm sq Connector Large sized swivel 8 pin Dimensions 163 mm 6 42 80 mm 3 15 Shipping Weight Approx 12 Ibs Included Accessories CM49 Plush Oak Box Historical Yoke Mount Historical Power supply Original large Tuchel connected mic cable Comes standard with the M7 capsule ...

Отзывы: