wtw MIQ/24V Скачать руководство пользователя страница 9

MIQ/24V

Installation

3 - 1

ba64114e02

08/2006

3

Installation

3.1

Scope of delivery

The scope of delivery of the MIQ/24V is listed in the I

NSTALLATION

 

chapter of the system operating manual.

3.2

Installation in the IQ S

ENSOR

 N

ET

The IQ S

ENSOR

 N

ET

 provides a number of options for integrating the 

MIQ/24V mechanically and electrically in the system (stacked 
mounting, distributed mounting, etc.). The individual types of instal-
lation are described in detail in the I

NSTALLATION

 chapter of the system 

operating manual.

Note

To achieve optimum heat transfer, it is recommended to always place 
the power supply module at the back of a module stack.

Note

If there are several power supply modules in the IQ S

ENSOR

 N

ET

, it is 

helpful if all the power supply modules are connected to a single power 
supply. As a result, the system can be easily switched on and off from 
a single location.

3.3

Connecting the 24 V AC/DC supply

Warning

If the power supply is connected incorrectly, it may represent a 
danger to life from electric shock. Pay attention to the following 
points during installation:

!

!

!

!

The power supply must fulfill the specifications given on the 
nameplate and in chapter 5 T

ECHNICAL

 

DATA

 (Safety Extra Low 

Voltage SELV).

!

!

!

!

The MIQ/24V may only be connected to the 24 V AC/DC supply 
by a trained electrician.

!

!

!

!

The connection of the MIQ/24V may only be carried out when 
the supply is not carrying any voltage.

!

!

!

!

When installed in a building, a switch or power switch must be 
provided as a disconnecting device for the MIQ/24V. 
The interrupt facility must:

– be installed in the vicinity of the MIQ/24V, easily accessible 

by the user, and 

– identified as a disconnecting device for the MIQ/24V.

Содержание MIQ/24V

Страница 1: ......

Страница 2: ...tween this operating manual and your instrument Also we cannot guarantee that there are absolutely no errors in this manual Therefore we are sure you will understand that we cannot accept any legal cl...

Страница 3: ...1 1 2 Features of the MIQ 24V 1 2 2 Safety instructions 2 1 2 1 Authorized use 2 2 2 2 General safety instructions 2 2 3 Installation 3 1 3 1 Scope of delivery 3 1 3 2 Installation in the IQ SENSOR N...

Страница 4: ...List of contents MIQ 24V 0 2 ba64114e02 08 2006...

Страница 5: ...l has a modular structure like the IQ SENSOR NET system itself It consists of a system operating manual and the operating manuals of all the components used Please file these component operating manua...

Страница 6: ...cs as all MIQ modules regarding stability leakproofness and weather resistance It also provides the same wide variety of instal lation options stacked mounting canopy mounting tophat rail mounting etc...

Страница 7: ...in the vicinity of the IQ SENSOR NET system Special user qualifications The MIQ 24V may only be connected to the 24 V AC DC supply by a trained electrician General safety instructions Safety instructi...

Страница 8: ...fe and secure technical condition Function and operational safety The failure free function and operational safety of the MIQ 24V is only guaranteed if the generally applicable safety measures and the...

Страница 9: ...wer supply modules are connected to a single power supply As a result the system can be easily switched on and off from a single location 3 3 Connecting the 24 V AC DC supply Warning If the power supp...

Страница 10: ...f as closely as possible to the cable gland Warning No free wires must be allowed to project into the housing Other wise there is a danger of electric short circuit that may cause fire Always cut off...

Страница 11: ...ine through the cable gland into the module housing 8 Connect the wires 1 and 2 to the terminal strip Make sure that the cable assignment agrees with the specification on the ter minal label under the...

Страница 12: ...tric short circuit that may cause fire Always cut off any wires that are not in use as closely as possible to the cable gland Fig 3 3 Closing the cable opening 10 Close the module 11 Screw the other c...

Страница 13: ...4 1 Maintenance The MIQ 24V requires no special maintenance The general mainte nance of IQ SENSOR NET components is described in the IQ SENSOR NET system operating manual 4 2 Cleaning The cleaning of...

Страница 14: ...Maintenance and cleaning MIQ 24V 4 2 ba64114e02 08 2006...

Страница 15: ...nnection 2 pole Line cross section of connection Europe 1 5 4 0 mm2 USA AWG 14 12 Fuse rating on the operator side 16 A maximum Power consumption Approx 25 W Output voltage Max 24 VDC via the IQ SENSO...

Страница 16: ...on the overall power requirement of the system see sys tem operating manual section PRINCIPLES OF AN OPTIMUM INSTALLATION Instrument internal fuses 5 x 20 T 1 6 A with UL approval Manufacturer Littlef...

Страница 17: ......

Страница 18: ...Wissenschaftlich Technische Werkst tten GmbH Dr Karl Slevogt Stra e 1 D 82362 Weilheim Germany Tel 49 0 881 183 0 49 0 881 183 100 Fax 49 0 881 183 420 E Mail Info WTW com Internet http www WTW com...

Отзывы: