background image

5-11

Confi guration

As shown in Figure 5.5 and Figure 5.6, the Serial Parameters Menus allow you 

to define the following parameters:

Note:

  When the baud rate, data bits, parity or stop bits settings 

are changed via the console port, newly selected parameters will 

not be applied until the user exits and then re-enters  

command mode.

• 

Baud Rate:

  The Baud Rate for the serial Console Port.   

(Default = 9600 bps.)

• 

Data:

  The Data bits setting for the serial Console Port.   

(Default = 8 Bits.)

• 

Parity:

  The parity setting for the serial Console Port.  (Default = None.)

• 

Stop:

  The stop bits setting for the serial Console Port.   

(Default = 1 Bit.)

• 

Serial Port Mode:

  Sets up the NBB Console Port for use with either a 

local PC ("Console") or an external modem ("Modem").  Note that when 

the Serial Port Mode is set to "Modem" the modem initialization string 

will be sent every 15 minutes.  (Default = Console.)

• 

Modem Initialization String:

  Defines a command string (up to 

32 characters long) which can be sent out the serial Console Port 

to initialize an external modem.  If the Serial Port Mode is set to 

"Console", the modem initialization string will not be sent.  For more 

information on initialization commands, refer to the user’s guide for 

your modem.  (Default = 

ATE0M0Q1&C1&D2S0=1

)

Note:

  The Modem Initialization String cannot begin with a 

forward slash (

/

) or backslash (

\

) character, and cannot include 

non-printable characters or quotation marks.

Содержание NBB-1600

Страница 1: ...WTI Part No 13406 Rev B NBB 1600 Series NetworkBootBars Models NBB 1600 NBB 1600 CE Firmware Version 1 41 and Higher User s Guide...

Страница 2: ......

Страница 3: ...protection and supply wiring GROUNDING Reliable earthing of this equipment must be maintained Particular attention should be given to supply connections when connecting to power strips rather than di...

Страница 4: ...o an outlet on a circuit that is different from the one used by the receiver Consult the dealer or an experienced radio TV technician for help This device complies with Part 15 of the FCC rules Operat...

Страница 5: ...ameters Menu 5 10 5 3 3 The Plug Parameters Menus 5 12 5 3 3 1 Plug Passwords and Co Location Features 5 14 5 3 3 2 The Boot Sequence Delay Period 5 15 5 3 4 Network Parameters Menus 5 16 5 3 4 1 IP S...

Страница 6: ...erface 5 7 5 5 Serial Parameters Menu Web Browser Interface 5 10 5 6 Serial Parameters Menu Text Interface 5 10 5 7 Plug Parameters Menu Web Browser Interface 5 12 5 8 Plug Parameters Menu Text Interf...

Страница 7: ...ational passwords the System Administrator Level which allows access to all con guration and switching functions and the User Level which only allows access to assigned plugs and cannot be used to cha...

Страница 8: ...ircuit 30 Amps total The NBB 1600 CE is intended for 230 VAC operation and can switch up to 10 Amps per power circuit 20 amps total Aside from voltage and load differences all other features function...

Страница 9: ...Description As shown in Figure 2 1 the NBB 1600 unit includes power outlets LEDs and a manual control button The items in Figure 2 1 are described on the following page Figure 2 1 NBB Unit Model NBB...

Страница 10: ...e On in order for the NBB to function Note that this switch is not used to set the On Off status of the switched outlets Switched Plugs and Plug Indicators Model NBB 1600 Sixteen 16 115 VAC outlets sp...

Страница 11: ...the NBB s Circuit A and Circuit B inlets and then connect the cables to an appropriate power supply The NBB 1600 will support up to 15 Amps maximum per power circuit for a total load of 30 Amps The N...

Страница 12: ...st setting up network parameters providing that you are contacting the NBB from a node on the same subnet When attempting to access the NBB from a node that is not on the same subnet please refer to S...

Страница 13: ...cs ON 5 unde ned unde ned ON 0 5 Secs ON 6 unde ned unde ned ON 0 5 Secs ON 7 unde ned unde ned ON 0 5 Secs ON 8 unde ned unde ned ON 0 5 Secs ON 9 unde ned unde ned ON 0 5 Secs ON 10 unde ned unde ne...

Страница 14: ...indicating that the command has been successfully completed Leave Plug 1 in the Off state and then proceed to the next step c Switch Outlet On From the Web Browser Interface select the button in the O...

Страница 15: ...e should only be operated with the type of power source indicated on the instrument nameplate If you are not sure of the type of power service available please contact your local power company Reliabl...

Страница 16: ...le Port Next refer to Section 5 3 2 and set the Serial Port Mode to Modem If necessary you may also wish to rede ne the Modem initialization command at this point as described in Section 5 3 2 Please...

Страница 17: ...Mode or User Mode If the System Password is entered the System Mode will be active If a Plug Password is entered the User Mode will be active The System Password is de ned via the General Parameters...

Страница 18: ...hree different methods for accessing command mode via network via external modem or via local console The Web Browser Interface is only available when the NBB is contacted via network and the Text Int...

Страница 19: ...then press Enter 3 Password Prompt The NBB will display a prompt which asks for your name and password a User Name If you have not previously de ned a user name then this eld should be left blank A u...

Страница 20: ...ty Make certain your communication program is set for the appropriate baud rate bits parity and Comm Port a Via Modem Start your communications program Dial the external modem connected to the NBB Wai...

Страница 21: ...ction 5 3 4 1 or that unit is operating on a 100Base T network that does not autosense for 10Base T devices see Section 4 4 2 Password If the System Password has been de ned the unit will display the...

Страница 22: ...the desired menu When the con guration menu appears key in the number or letter for the parameter that you wish to de ne and follow the instructions in the resulting submenu Note the following To exit...

Страница 23: ...Password unde ned 2 User Name unde ned 3 Site ID unde ned 4 Command Echo On 5 Inactivity Timeout 2 Mins 6 Command Con rmation On 7 Automated Mode Off 8 Manual Switch Button On 9 Command Prompt NBB A D...

Страница 24: ...ote that the User Name is only required when the unit is accessed via the Web Interface 16 Characters Default unde ned Notes If a User Name is de ned then users who log in with a Plug Password User Mo...

Страница 25: ...suppressed and users are able to access System Level menus and control plugs without entering a password If security is a concern and the Automated Mode is required it is recommended to use the IP Sec...

Страница 26: ...e Setup button to access the Setup Menus and then click the Serial Parameters button The Serial Parameters Menu will be displayed as shown in Figure 5 5 Text Interface Type C and press Enter The Seria...

Страница 27: ...Port Default 1 Bit Serial Port Mode Sets up the NBB Console Port for use with either a local PC Console or an external modem Modem Note that when the Serial Port Mode is set to Modem the modem initial...

Страница 28: ...nus then click the Plug Parameters button The Plug Parameters Menu will be displayed as shown in Figure 5 7 Text Interface Type P n and then press Enter Where n is the number or name of the plug you w...

Страница 29: ...at this password does not allow access to con guration functions 16 Characters Default unde ned Note Passwords cannot contain nonprintable characters spaces colons plus signs or quotation marks Boot S...

Страница 30: ...o issue switching and reboot commands for the corresponding plug and every other plug that shares this same password For example if the plug password switch is de ned for plugs 1 2 and three then if a...

Страница 31: ...ssume that the Boot Sequence Delays for each plug have been set as follows Plug 1 1 Second Plug 2 2 Seconds Plug 3 5 Seconds Plug 4 1 Minute Plug 5 1 Second If an On command is applied to the rst ve p...

Страница 32: ...pend on the con guration of your individual network Contact your network administrator for appropriate settings The Network Parameters Menu allows the following parameters to be de ned Except where no...

Страница 33: ...Interface NETWORK PARAMETERS 1 IP Address 207 212 30 80 2 Subnet Mask 255 255 255 0 3 Gateway Address 207 212 30 1 4 Send MSS 536 5 IP Security MAC Address 00 09 9b 00 9b 82 Enter Selection Press ESC...

Страница 34: ...urity masks along with the selected permit deny action for each mask a Each Security Mask prompt de nes a speci c IP address or range of addresses Each Mask Action prompt de nes the permit deny action...

Страница 35: ...ly by addresses that begin with 192 deny access to 192 1 1 5 Security Mask 1 255 255 255 255 Mask 1 Action Deny Security Mask 2 192 255 255 255 Mask 2 Action Permit Security Mask 3 192 1 1 5 Mask 3 Ac...

Страница 36: ...yed as shown in Figure 5 13 The Telnet Parameters Menus allow the following parameters to be de ned Please note that all parameters listed here are available via both the Web Browser Interface and Tex...

Страница 37: ...cess the con guration menus and then click the Web Server Parameters button The Web Server Parameters Menu will be displayed as shown in Figure 5 14 Text Interface Type W and press Enter The Web Serve...

Страница 38: ...the NBB will prompt you to save parameters before exiting from Command Mode At this point the NBB offers the options to Save parameters continue without saving or revert to the previously saved param...

Страница 39: ...The Plug Status Screen Figure 6 1 lists the current On Off status of the NBB s Switched Outlets and provides a series of radio buttons which are used to control switching and rebooting of the outlets...

Страница 40: ...To set all plugs to their user de ned Power Up Default On Off status click the Default button in the All Plugs row and then click Apply Note that in order for this command to function Power Up Defaul...

Страница 41: ...e Normally the Plug Status Screen will also be redisplayed each time a command is successfully executed Note however that if desired the Automated Mode See Section 6 4 can be enabled to suppress the d...

Страница 42: ...er commands are successfully completed When switching or reboot operations are initiated Boot Sequence Delay times will be applied as described in Section 5 3 3 2 Network Boot Bar v1 41c Site ID unde...

Страница 43: ...ug Note that the BOOT command can also be entered as BO For example BOOT 1 or BO ATMSWTCH 4 Set Plugs to Power Up Defaults Type D and press Enter Plugs will be set to their default On Off status Power...

Страница 44: ...e password that was used to access command mode 1 Several Plugs To apply a switching or reboot command to several plugs enter the numbers or names for the plugs separated by a plus sign For example to...

Страница 45: ...r switching functions without human intervention When the Automated Mode is enabled the ON OFF BOOT D and X commands are executed without a Sure con rmation prompt and without command response message...

Страница 46: ...Prompt Suppressed All commands are executed without prompting for user con rmation 4 Error Messages Suppressed If the Enter key is pressed without entering a command the NBB will not respond with the...

Страница 47: ...c which allows downloading of ASCII les Note Although this function is available only via the Text Interface parameters that have been de ned via the Web Browser Interface will also be sent to the ASC...

Страница 48: ...pload an ASCII text le 4 Upload the le with the saved parameters If necessary key in the le name and directory path 5 When the upload is complete make certain to terminate the communications program s...

Страница 49: ...ore beginning this upgrade procedure 1 Obtain the update le Firmware modi cations can either be mailed to the customer on a CDR or downloaded from WTI Place the upgrade CDR in your disk drive or copy...

Страница 50: ...6 Incomplete Upload If the upload is interrupted times out or if the update le becomes corrupted during transfer the NBB will display a screen which asks for con rmation before proceeding To proceed t...

Страница 51: ...Apx 1 A Interface Descriptions A 1 Console Port Interface Figure A 1 Console Port Interface...

Страница 52: ...wer Input Output Model NBB 1600 CE 230 VAC AC Input Two Separate Circuits 10 Amps Max per Circuit 20 Amps Total Voltage 208 240 VAC 50 60 Hz Connectors Two 2 IEC 320 C14 Inlets Line Cords Supplied AC...

Страница 53: ...odel of the unit its serial number and a description of its symptoms If the unit should need to be returned for factory repair it must be accompanied by a Return Authorization number from Customer Ser...

Страница 54: ...e trademarks of their respective companies Information and descriptions contained herein are the property of Western Telematic Inc Such information and descriptions may not be copied disseminated or d...

Страница 55: ...eters 7 1 Duplex Mode 5 8 E Error Messages 6 8 Ethernet Port 2 2 4 2 External Modem 4 2 5 11 F Firmware Setup 5 1 to 5 18 Firmware Upgrade 8 1 to 8 2 Front Panel 2 1 to 2 2 G Gateway Address 5 16 Gene...

Страница 56: ...eters 7 2 S Saving Parameters 5 22 7 1 Sectors 8 1 Security 5 1 5 18 to 5 19 Segment Size 5 16 Send MSS 5 16 Sequence Delay 5 13 to 5 14 5 15 Serial Parameters Menu 5 10 to 5 11 Serial Port 2 2 4 2 Se...

Страница 57: ...Notes 1 Notes...

Страница 58: ...Notes 2 NBB 1600 Series Network Boot Bars User s Guide Notes...

Страница 59: ......

Страница 60: ...5 Sterling Irvine California 92618 949 586 9950 Toll Free 1 800 854 7226 Fax 949 583 9514 http www wti com...

Отзывы: