Clock Page
Use the Clock page to set the clock source and sample rate for the device and to assess clock status.
.
SOURCE
sets the requested clock source.
Internal
The device itself provides the SEO clock.
External WC
Clock is provided by an external device via the Word Clock Input connector.
Sync over Ethernet
The device receives clock from the SoundGrid network.
SAMPLE RATE
sets the sample rate when Clock Source is set to Internal. Range: 44.1 / 48 / 88.2 / 96 kHz.
If the device is the network (SOE) clock master, as determined in the Device Racks of the
SoundGrid host, then this setting determines the sample rate of the SoundGrid network.
If Clock Source is set to an external clock source, you cannot change the sample rate from the
host. The Sample Rate menu is grayed out and inoperative.