Installation & Operation Manual
Wall Mounted- Outdoor Drinking Fountain / Bottle Filler
WODF-1WM Series / CWBF-1WM Series
Willoughby Stainless Fountains
TOLL FREE
(800) 428-4065
● LOCAL
(317) 875-0830
● FAX
(317) 875-0837
Page 11
Rev. 3/2018
www.willoughbystainlessfountains.com
Installation Instructions
Step 1: Fixture Installation
Note: the WODF outdoor drinking fountain is to be mounted on a flat, level surface
(concrete or otherwise) with an adequate support structure.
Note: refer to Rough-In Dimensions for locating plumbing connections.
1.) Install service shut-off valve in water supply line (valve not furnished).
2.) Locate and install bottle filler using 1/2"-13 x 4" concrete anchors (anchors not furnished).
3.) As noted previously, flush the water supply line with clean drinking water before making final
connections to the drinking fountain.
4.) Connect water supply line to inline strainer inside drinking fountain using 3/8" plastic tubing
(extra tubing not furnished). Push tube straight into fitting on filter about 3/4" until it reaches a
positive stop. Water supply connection must comply with local codes.
5.) Connect the drain line to drainage system. Drain is to be 1-1/2" IPS minimum to a porous gravel
flll or main sewer line located below frost line. Installer to provide waste trap downstream of drain
connection. Drain and waste trap must comply with local codes.
6.) Turn on water supply and check both the water supply lines and drain lines for leaks.*
*If you have a Push Button model fountain or bottle filler, go to
Step 2A
If you have a Battery Operated Infrared Sensor model bottle filler, go to
Step 2B