CAT5  intercom

 

system

 

gate station manual

Thank

 

you

 

for

 

choosing

 

WRT

.

Please read this manual

before using. WRT reserves the right to change 
specifications or designs described in this manual 
without notice and obligation.

I Z M - 2 1 2 C S 4 - I P M

R

Содержание IZM-212CS4-IPM

Страница 1: ...tem gate station manual Thank you for choosing WRT Please read this manual before using WRT reserves the right to change specifications or designs described in this manual without notice and obligation IZM 212CS4 IPM R ...

Страница 2: ...1 0 Features Functions 2 0 Equipment Description Video Gate Station 3 0 Caution 4 0 Installation 5 0 Operation 6 0 Specification 7 0 Terminal Description 8 0 Trouble Shooting 9 0 Wiring 1 2 2 3 4 5 6 22 23 24 25 26 28 ...

Страница 3: ...or 2 Max capacity is 1016 door phones 3 Color video 4 4 0 LCD Display 5 Soft coding form it is freed from building structure 6 Fashion keyboard with button dust proof long service life optional 7 Can call talk with Guard Center and Guard Center can remote unlock 8 Unlock by cards 9 Snapshot function optional 1 Burglar alarm optional 0 1 Door contact alarm 1 12 Lift control optional 13 CCD with nig...

Страница 4: ...ntroller and access control 10 Lightning terminal GND 12 Volume adjustment 11 Socket for power input unlock signal output 14 Socket for door contact and door release 13 To network switch connector Front View Back View 2 1 5 6 3 4 7 8 9 14 10 GND 13 12 11 18V GND MENCI DOOR GND UNLOCK B A J3 J13 J15 J21 J24 J20 J25 J22 EARTH GND Welcome Please input Room No Input room ID for call 00 for center INPU...

Страница 5: ...city from the weak Keep away from the elevator and TV cables over 50m Use iron tube and do not use the same wire tube for strong and weak electricity The ends of the iron tube should be buried in 3m deep down the ground so as to raise capability of anti jamming and lighting 10 In order to avoid interference it is better to use wire tube and separate other interferences For easy maintenance and sta...

Страница 6: ...t in the cement Figure 2 3 Unscrew 4 screws from Gate Station and separate the two aluminum cases of gate station Fiture3 4 Connecting all Gate Station wires then fix Gate Station on the bottom cover and the aluminum cases with screws Figure 4 wall 1 2 3 4 130 0mm 378 0mm Wire tube 82 0mm Wall Bottom case Welcome Please input Room No Welcome Please input Room No Input room ID for call 00 for cente...

Страница 7: ...screw 4 screws from Gate Station Figure 2 Drill a wire hole at the bottom case insert the transmission wires through the wiring hole 3 Connecting all wires and press the Gate Station from the front of the door Fix the bottom case with screws 4 Fix Gate Station with screws Welcome Please input Room No Input room ID for call 00 for center INPUT ROOM ID Welcome Please input Room No Input room ID for ...

Страница 8: ...pied data file in case of any damage of computer system 4 Every twice press the button not more than 60 seconds or it will exit operating state When standby the screen will show The Gate Station works after all parameters are correct Press first then press and release the two keys at the same time The screen will show Input 8 digits managing PIN setting last time If it is first time to input it sh...

Страница 9: ...setting Configure or modify the local network parameter Press 1 on the basic setting menu the screen shows 1 SN 2MAC 3VER 4Device ID 5Local IP 6Subnet mask 7Gateway Press to return Press to next page 0 System info 5 Password setting 1 Network setting 6 Function ON OFF 2 Device No 7 Time setting 3 Room Format 8 Access control 4 Room Table Edit 9 Language 1 Restore factory setting 2 Restart 3 Return...

Страница 10: ...tion etc other IP address no need to input Press to clear up the data in the input box or exit input status Device NO Press 2 on the basic setting menu the screen shows Press number keys it can clear up the data in the related input box and input network parameters according to actual distribution After finished input the data each time if the data is legal the screen will prompt that modify succe...

Страница 11: ... is anything else it is sub Gate Station In a building no matter how many outdoor stations there must be a Gate Station named 01 Press to clear up the data in the input box or exit input status Room Format Press 3 on the basic setting menu the screen shows Press 0 or 1 select room format as digit or alphabet means selected press to return previous menu or exit automatically after 60 seconds Room T...

Страница 12: ...the decoder 1 is used for room 0101 0108 on the 1st floor the decoder 2 is used for room 0201 0208 on the 2nd floor until the decoder 12 is used for room 1201 1208 on the 12th floor Then the decoder 13 is used for room 9 12 on the 1st and 2nd floor the decoder 14 is used for room 9 12 on the 3rd and 4th floor Until the decoder 18 is used for room 9 12 on the 11th and 12th floor Because the port nu...

Страница 13: ... 8 to 0209 0212 The modification of decoder 13 is completed The modification of decoders 14 18 is the same as above Ports 1 8 of the decoders 01 99 which connect with Gate Station correspond to room NO 01 08 automatically Ports 1 8 of the decoders 100 127 correspond to room NO 09 16 automatically port number which is anomalistic must be modified Password setting set local super password and unlock...

Страница 14: ...sword Then the screen prompt to confirm super password again If entered two new super passwords are the same it will prompt that new super password is modified successfully Note Original password is 88888888 Enter the setting menu again and must use new password Please input new password 1 Modify super password 2 Modify unlock password 3 Return Operation Operation ...

Страница 15: ... prompt modified successfully it means this group data set succesfully Snapshot ON OFF whether to enable snapshot function If this function enabled on Gate Station and the center exit the room NO address table of the tenant the Entrance Station or sub Gate Station call the tenant in this unit 20 seconds it will snap a picture 1 Snapshot ON OFF 2 Disarm by card 3 Return 1 0 0 OFF 1 ON Operation Ope...

Страница 16: ...ns the group data set successfully Under non input state press 3 or to return previous or exit automatically after 60 seconds Note Time setting will not be saved Time will be default after restart but time synchronized through center after connecting the power supply Access control It is effective for Gate Station with access control including issue card by room NO issue card by swiping delete car...

Страница 17: ...rface the screen will show Swipe the card at the induction zone according to the prompt the screen prompts modified successfully it means the card deleted successfully the user could continue deleting other cards Press to return to previous menu c Issue card by room NO Issue card by room NO of the tenant Press 3 on the Access Control interface the screen will show 1 Issue card by swiping 2 Delete ...

Страница 18: ...oom NO of the tenant Press 4 on the Access Control interface the screen will show Input 6 digits 3 digits floor NO 3 digit room NO for example 001001 the room NO of tenant Then press to confirm it means deleted successfully Note The tenant could use the card which is issued successfully to unlock The card which is deleted will become invaildly can not open the electric lock until the card is regis...

Страница 19: ...Note Restore factory setting will delete all access control cards Decoder room NO table serial number and network parameter will be default values Please be cautious Restart Restart Gate Station Press 2 on the basic setting menu on page 2 the screen will show Press 1 then press Gate Station will restart automatically Door contact Alarm There is a door contact terminal MENCI GND at the socket J24 w...

Страница 20: ...volume adjust electronic equipment at the back of Gate Station There is a terminal ocket J he back of Gate Station DOOR and GND at the s 24 which is at t it is used to connect to the button When short circuit can open the door DOOR and GND are After all settings are completed please restart Gate Station to refresh datas Operation 18 Operation ...

Страница 21: ...t 0302 the screen display the corresponding number at the same time After finished input the room number press to confirm if the number does not exist the screen will prompt If the number is correct and the line is not busy it will ring out the screen will show When the tenant answers the phone the screen will show 0302 Input room ID for call 00 for center Room NO does not exit Calling to hang up ...

Страница 22: ...cally Calling Tenants Divert on When the station calls the tenant and the line is not busy the system will transfer the call to Guard Center You can also leave a message to Guard Center the message will be delivered to the household Calling Center Press 00 you can call the Center sequence of call Guard Station Sub Guard Station Guard Center Back up Guard Center Operation Operation Input room ID fo...

Страница 23: ...call to the Center If the Center no answer or is busy it will transfer the call to the Back up Center If the Center is busy no Back up Center it will prompt busy tone please call later Unlock by password The tenant could unlock by password The method is to input passwords For example the unlock password is 00000001 input 00000001 to unlock If input correct password the screen will show Note If unl...

Страница 24: ...ard to close to the induction zone Di Di tone can be heard if succeed the screen will show If IC card failed to register Du Du tone can be heard the screen will prompt invalid card Input room ID for call 00 for center Unlock please close the door Operation Operation ...

Страница 25: ...rt Protocol Transmission distance IC Access Time IC Access Distance Capacity of cards Defence Grade External Dimensions Size of Bottom case 18VDC 300mA About 60s 45 95 5 0mA 38 IP33 147 393 80 I mm ncluding bottom case 133 377 65mm 30 C 55 C 0 0 30mV 20mm RJ45 TCP IP For details read the requirement of wire size 100ms 3000 320 RGB x240 4 0 inch 5 16U 500 wire Automatic backlight compensation PAL ...

Страница 26: ...ion UNLOCK GND 18V DOOR GND MENIC A B GND J24 J20 J25 J13 J21 Power supply input supply DC 18V for the station Power supply input Unlock signal output 12V when unlock Unlock signal input GND To Door Contact 485A data wire 485B data wire To decoder GND To network switch ...

Страница 27: ...rd is damaged 3 whether the method of swiping card is correct and Gate State is damaged The distance from IC card to induction zone must 30mm If all the cards can not unlock check the wires of Gate Station If just one card can not unlock it means the card is not registered or deleted records or damaged All the tenants in a building can not unlock Check connection from Gate Station to power supply ...

Страница 28: ... wire Network Cable System power supply wire Electric lock wire Please pay attention to transmission distance and wire size Except special electric lock Alternator Dual power supply please add Fiber Converter if over 100m RVV2 0 5mm2 RVV2 0 75mm2 RVV2 0 75mm2 1 15m 15 30m 30 100m Wire between power supply and door phone Wire between decoder and door phone Please pay attention to transmission dista...

Страница 29: ...c lock Electric lock Electric lock 2 core 2 core 2 core 2 core 2 core 2 core 3 core 3 core 3 core 3 core Unlock power supply Unlock power supply Unlock power supply Unlock power supply Power supply Power supply decoder decoder decoder decoder Door phone Door phone Door phone Door phone Door phone Door phone Door phone Door phone UTP cable Multi fiber copper wire LAN 1橙白 视频 4蓝 音频接收 7棕白 音频地 2橙 视频地 5...

Страница 30: ...re E lock wire 18V GND PUSH NO NC 28V GND E lock HD V18 PD V28 To lift controller or access control To network switch To GND Door Contact Door release GND 28V Businput Bus output 1 2 4 8 16 32 64 V C C R X D T X D G N D 1 2 3 4 To next decoder bus input To other decoders To door phone To door phone Floor code App upgrade ...

Страница 31: ... Add WRT Industrial Base Dafu Industrial Park Guanguang Rd GuanLan Town BaoAn District ShenZhen China Tel 86 755 29576113 Fax 86 755 29576023 Http www wrtsz com Shenzhen WRT Intelligent Electrical Appliance Co Ltd ...