Western Reserve Controls, Inc.
1782-JDO User’s Manual
PRELIMINARY
23
Table 6-3
Identity Object Instance Attributes (Instance 1)
Attribute
ID
Access
Rule
Name
DeviceNet Data
Type
Description of Attribute
Value
1
Get
Vendor
UINT
ODVA Vendor Number for this
product
9 = WRC
2
Get
Device Type
UINT
ODVA Communications Device Type
12 = Comm.
Adapter
3
Set
Product
Code
UINT
WRC Unique Product Code Number 701 = 2bd
hex
4
Get
Revision
STRUCT of:
Revision of this device
Major
Revision
USINT
>=5
Minor
Revision
USINT
>=1
5
Get
Status
WORD
Summary status of device
6
Get
Serial
Number
UDINT
WRC Unique Device Serial Number
7
Get
Product
Name
SHORT_STRING ASCII Name of product
1782-JDO
10
Get/Set
Heartbeat
Interval
USINT
The interval in second that the device
generates a heartbeat message. A
value of 0 disables heartbeat
generation.
0
Table 6-4
Identity Object Common Services
Service
Code
Class
Instance
Service Name
Description of Service
O5
hex
Yes
Yes
Reset
Invokes the Reset Service for the
device.
OE
hex
Yes
Yes
Get_Attribute_Single
Returns the contents of the specified
attribute.
10
hex
No
Yes
Set_Attribute_Single
Modifies an attribute value.