To ensure proper use of this product, please read the instructions carefully 

before using. 

• The optimal measuring distance for this product is 1 yard. 
• To ensure measurement accuracy, please use the product in an operating 

environment of 15

° 

C - 30

° 

C, <85%  RH  (non-condensing).

• Please use the product indoors without wind. 
• When changing to a new environment, please tum on the product and leave

it for 10 to 15 minutes before measuring. 

• The ambient temperature for measuring must be stable.  Do not measure in

places with large airflow such as fans and air outlets. 

• When the measured object comes  from a place  with a large temperature

difference from the measurement environment, keep it in the measurement
environment for 10 to 30 minutes before measuring. 

• The product tests the surface temperature of the object.  If temperature 

compensation is needed, please adjust in the Settings menu. 

• The product has a self-calibration function.  If the reading jumps quickly, please 

read the temperature after it gets steady. 

• After measuring extremely high or low temperature objects, please leave the

product for 10 minutes before next use.

• Do not use the product in places with strong sunlight or electromagnetic

interference. 

• Please do not use the product in flammable, explosive, steamy, wet or corrosive 

environments.

• Please stop using the product if it is damaged or modified to avoid inaccurate 

measurement results. 

• Please use the correct emissivity to obtain accurate temperature readouts.
• To ensure  accuracy  of the product,  please warm it up for 10 to 15 minutes

before measuring if it has not been used for a long time. 

• When being charged, the internal temperature of the product rises, which will 

lead to inaccurate temperature measurement.  So, it is not recommended to
take measurements during or right after charging the product. 

Содержание NCTIPFHF01

Страница 1: ...P N 110401109196X NCTIPFHF01 Professional Thermal lmager User Manual...

Страница 2: ...l imager In order to use this product safely and correctly please read this manual thoroughly especially the Safety Instructions part After reading this manual it is recommended to keep the manual at...

Страница 3: ...it in the measurement environment for 10 to 30 minutes before measuring The product tests the surface temperature of the object If temperature compensation is needed please adjust in the Settings men...

Страница 4: ...light button Left button Down button Up button Replay button Right button Back button SET button Tripod mounting hole NCTIPFHF01 User Manual 3 Display Display size 2 8 Display resolution 320 vertical...

Страница 5: ...n 3 Press the SET button to enter the Measurement menu 4 Press the up down button to select Center Spot center point measurement or Hilo Spot maximum and minimum temperature measurement 5 Press the SE...

Страница 6: ...s the SET button to turn off the point Press the back button to exit NCTIPFHF01 User Manual 5 4 Image Mode 1 Press the SET button to open the main menu 2 Press the left right button to select the II o...

Страница 7: ...and Time Date and Time 2020 03 16 15 39 Time for111 1t To set date and time Date and Time 2020 03 16 03 41 PM T1mr fo1rn 1t 1 Press the up down button to select the Date and Time option in the settin...

Страница 8: ...down button to increase or decrease the value 6 Press the SET button to save the current setting 7 Press the back button to exit Note For emissivity values of common materials please refer to the Com...

Страница 9: ...ck button to exit Note Do not remove or insert the SD card in saving pictures It is recommended to save no more than 1000 pictures so as not to affect the response speed of the product When the number...

Страница 10: ...NCTIPFHF01 User Manual NCTIPFHF01 User Manual...

Страница 11: ...Projection 1 Download and install the PC software 2 Connect the USB cable to the PC 3 Set the USB mode to USB Disk to browse pictures and analyze data through the PC software set the USB mode to USB...

Страница 12: ...distance Response time IR resolution Pixel size Color palette Infrared spectral band Field of view FOV Spatial resolution IFOV Thermal sensitivity NETO Frame rate Temperature measurement display Image...

Страница 13: ...or window 9 Common Emissivity Material Emissivity Material Emissivity Wood 0 85 Black paper 0 86 Water 0 96 Polycarbonate 0 8 Brick 0 75 Concrete 0 97 Stainless steel 0 14 Copper oxide 0 78 Tape 0 96...

Отзывы: