WQA WaterSTATION PuR100-7 Скачать руководство пользователя страница 1

#92673    Rev. 1/11

PuR100-7

Installation, Operation, Service Record and Warranty

Содержание WaterSTATION PuR100-7

Страница 1: ...92673 Rev 1 11 PuR100 7 Installation Operation Service Record and Warranty...

Страница 2: ...es do the job safely and which ones don t You need an easy to recognize trusted seal approval on the products that are safe to use and will perform as advertised There is a mark that tells you at a gl...

Страница 3: ...er keep container of WaterSTATION water in the fridge to be able to enjoy the cleaner fresher taste Alternatively take it directly from the tap Ice Cubes use WaterSTATION water to fill ice cube trays...

Страница 4: ...st 4 Maintenance Requirement 5 Installation Requirements 6 Installation Steps 8 Activating the System 17 Sanitization Procedures 18 Parts List and Drawing for PuR100 7 WaterSTATION 20 WaterSTATION Flo...

Страница 5: ...from water 9 250 L 92624 Fourth Stage TFC Membrane TFC Membrane 100 TFC GPD Membrane 10 Length Reduces TDS from water 37 000 L 92625 Fifth Stage Post Filter Inline Carbon Filter 10 Micron Carbon Filt...

Страница 6: ...e check all components for any damage that may have been caused by shipping 1 WaterSTATION Module 2 Shroud 3 Storage Tank 4 First Stage Sediment Filter 5 Second Stage GAC Carbon Filter 6 Third Stage C...

Страница 7: ...nded Service Intervals Replace filters as required or based on capacity listed on page 3 depending on feed water quality Replace membrane as required based on periodic TDS rejection tests 12 Module Su...

Страница 8: ...line only Note Conditioned water is preferred since it will extend the life of your TFC membrane Drain connection is accomplished using a waste water saddle valve which is designed to fit around a sta...

Страница 9: ...water to the WaterSTATION system Drain Saddle Valve is connected to the drain to remove reject water from the WaterSTATION system Tubing supplies feed and reject water Shroud to cover the WaterSTATIO...

Страница 10: ...g a Slide nut and sleeve onto tubing in that order b Install insert into plastic tubing c Install tube with insert and sleeve into valve body d Thread compression nut onto valve body tighten 5 Turn sa...

Страница 11: ...K INSTALLATION 1 Hand tighten the ball valve onto the WaterSTATION storage tank CAUTION Do not over tighten ball valve as this may strip threads or compromise the O ring seal 2 Slide compression nut o...

Страница 12: ...ill bit 3 Complete hole size by using a 1 1 4 chassis punch 4 Installation hole is ready install faucet A PILOT DRILL B SPRING LOADED PORCELAIN SAW C FINISH HOLE SAW Figure 6 Installation STEPS CONT D...

Страница 13: ...tighten 6 Install faucet connector Apply food grade teflon tape packaged with faucet onto faucet nipple Install 3 8 white tube into faucet connector 7 Trim 3 8 white tube to desired length Install 3...

Страница 14: ...wrench provided Slide the wrench from the left hand side onto the cap 3 Hold the membrane upside down cut the plastic bag at the bottom 4 The bottom tip of the membrane must sit firmly in the protrud...

Страница 15: ...market by TO TANK sticker on the Tee of the WaterSTATION Module Cut the tube if required Route this white tubing through the hole located at the WaterSTATION bracket as shown below 3 8 Quick Connect...

Страница 16: ...ted through the hole of the bracket 4 Connect the 1 4 white tubing from the air gap barb of the faucet to the WaterSTATION Module The location of this connection is market by TO DRAIN sticker on the f...

Страница 17: ...r potable water use NOTE Before installing the ceramic filter the drain flush valve needs to be open with inlet water ON and the TFC membrane needs to be flushed for 15 minutes This will remove fines...

Страница 18: ...NG the ceramic filter is very fragile and requires gentle handling 3 Install the O ring provided with the ceramic cartridge on to the thread of the ceramic cartridge 4 Screw the ceramic filter on to t...

Страница 19: ...c filter installed 6 Let the system stand unused for 24 hours 7 Flush the system for 10 minutes CAUTION Make sure all water supply lines drain lines and fittings are secure and free from leakage 1 Ope...

Страница 20: ...bag 7 Remove filter membrane housing O rings and wash them with cleaning solution Rinse them well with clean potable water Inspect them for damage i e nicks scratches Replace damaged O rings 8 Clean...

Страница 21: ...rom cartridge and discard Replace each filter housing as each cartridge is installed 21 Turn feed water valve slowly to open position 22 Confirm system is producing water Unit will be sending rinse wa...

Страница 22: ...22 92646 2 Elbow 1 4 QC X 1 4 Stem 23 92647 1 Adapter 1 4 QC X 1 4 NPT 24 92648 3 Tee 1 4 QC Part Item Qty Description 25 92649 1 Elbow 1 4 Stem X 3 8 QC 26 92650 1 Elbow 1 4 NPT X 3 8 QC 27 92651 2 A...

Страница 23: ...21 Parts List and Drawing 8 22 32 27 70 25 24 21 15 21 36 3 9a 10 21 5 6 21 19 16 4 1 9c 9b 23 20 22 26 78 17 24 24 80 21...

Страница 24: ...ONTROL PART 92654 DRAIN LINE TUBING AIR GAP FAUCET MODELS ROUTE TUBE THROUGH FAUCET CONNECTIONS PRODUCT WATER CHECK VALVE PART 92643 MODULE INLET MEMBRANE HOUSING TFC MEMBRANE PART 92624 STAGE 4 REJEC...

Страница 25: ...n from spigot to sufficiently flush filters b Contact dealer for revised product water TDS c Replace membrane Bad tasting water a Taste from glass or plastic containers b Post carbon filter cartridge...

Страница 26: ...te MM DD YY SED CAR BLOC Installed by Customer Initials MM DD YY MEM CAR CAL CER Installed by Customer Initials Serial ______________________________________ Installation Date ________________________...

Страница 27: ...ter system of equal or greater quality You pay only freight for repaired or replaced parts from our factory and local dealer charges including but not limited to labor charges travel and transportatio...

Страница 28: ......

Отзывы: