MT-10TDC-HV-C: #35094
Rev 17.2/12-21
16
Sealing the Pads on the Load
1)
1A
Place the power switch in the “on” position (
— fig. 1A).
1
Keep power switch in “on” position
(
)
throughout lift.
The vacuum pump will turn on, the low vacuum warning light will remain lit until the
vacuum pads seal. This is normal.
2)
2A
Place the pads in contact with the load
surface. Then place the vacuum control
valve lever
parallel
with the vacuum line
(ie, in the “attach” position —
, fig.
2A).
2
Keep control valve in “attach”
position
(
)
throughout lift.
Caution:
Any interruption of airflow
during lifter operation could cause a
load release and personal injury.
3) Press the lifter firmly against the load to help the activated pads begin to seal.
3
1..... If any powered component fails to function while the power switch is in the “on” position, examine the circuit breaker to determine whether it
has interrupted the electrical circuit to the component. Although you can reset the circuit breaker, the power interruption may indicate an
electrical problem that requires attention. Any fault must be corrected before resuming normal operation of the lifter.
2..... Do not place the vacuum control valve in the “attach” position unless the vacuum pads are contacting the load.
3..... Although a vacuum pad may become distorted during shipping or storage, this condition should correct itself with continued use.