20V Cordless Drain Auger   WX891 WX891.X

working period.

Helping to minimise your vibration and noise exposure risk.

Always use sharp chisels, drills and blades.

Maintain this tool in accordance with these instructions 

and keep well lubricated (where appropriate).

If the tool is to be used regularly then invest in anti 

vibration and noise accessories.

Plan your work schedule to spread any high vibration tool 

use across a number of days.

OPERATING INSTRUCTIONS

NOTE:

 Before using the tool, read the instruction 

book carefully.

INTENDED USE:

It is a handheld drain auger, used to dredge the 19-76mm 

of the pipes.

Assembly and Operation

Action

Figure

BEFORE OPERATION

Removing the battery pack

See Fig. A1

Charging the battery back

See Fig. A2

Installing the battery pack

See Fig. A3

OPERATION

Flexible shaft advances to the 

blockage

-- Adjust the switch correctly

See Fig. B

-- Extend the cable

NOTE: 

The harder you press, the faster 

the flexible shaft will rotate.

ATTENTION: Keep the tool head 

at most of 10cm of the pipe 

opening. If the distance is too long, 

it will cause the flexible shaft to be 

twisted and knotted. When tool 

head is difficult to approach the 

pipe, please use the front guide 

tube, preventing injury.

See Fig. C

Rotate flexible shaft and entangling 

the rubbish

See Fig. D

Retract the flexible shaft and bring 

out the rubbish

See Fig. E

CLEANING AND 

MAINTENANCE

Clean the rubbish on the flexible shaft and drain all the 

dirty water in the drum, store it in a shade and dry place. 

Fully charge battery after work. And store it in a shade 

and dry place.

STORAGE AND 

MAINTENANCE OF THE 

MACHINE

Before maintenance, please switch off and take off the 

battery pack!

After each use, rotate manually the drum and remove 

the waterproof plug. Erect tools with head down so that 

liquid will drain out and reinstall the waterproof plug.

Do remember to take off the wrench in case of tossing 

out next time.

Please clean the flexible shaft and drum carefully. If it 

is not to be used for a long time, please apply butter on 

the surface of the flexible shaft.

MAINTAIN TOOLS WITH CARE

Remove the battery before carrying out any 

adjustment, servicing or maintenance.

Keep tools sharp and clean for better and safer 

performance. Follow instructions for lubricating and 

changing accessories. Inspect tool cords periodically 

and if damaged, have repaired by authorized service 

facility. Your power tool requires no additional lubrication 

or maintenance. There are no user serviceable parts in 

your power tool. Never use water or chemical cleaners 

to clean your power tool. Wipe clean with a dry cloth. 

Always store your power tool in a dry place. Keep the 

motor ventilation slots clean. Keep all working controls 

free of dust.

Periodically clear dust and chips from guard and base to 

ensure proper performance.

FOR BATTERY TOOLS

The ambient temperature range for the use and storage 

of tool and battery is 0°C-45°C.

The recommended ambient temperature range for the 

charging system during charging is 0°C-40°C.

ENVIRONMENTAL 

PROTECTION

 

Waste electrical products must not be disposed 

of with household waste. Please recycle where 

facilities exist. Check with your local authorities 

or retailer for recycling advice.

Содержание WX891

Страница 1: ...SAFETY AND OPERATING MANUAL ORIGINALINSTRUCTIONS 20V Cordless Drain Auger WX891 WX891 X ...

Страница 2: ... unintentional starting Ensure the switch is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the p...

Страница 3: ...he cable is turning This can overstress the cable and may cause twisting kinking or breaking of the cable and may result in serious personal injury c Use latex or rubber gloves inside the gloves recommended by the manufacturer goggles face shields protective clothing and respirator when chemicals bacteria or other toxic or infectious substances are suspected to be in a drain line Drains may contai...

Страница 4: ...ad instruction manual Warning Wear ear protection Wear eye protection Wear dust mask Batteries may enter water cycle if disposed improperly which can be hazardous for ecosystem Do not dispose of waste batteries as unsorted municipal waste Do not burn Waste electrical products must not be disposed of with household waste Please recycle where facilities exist Check with your local authorities or ret...

Страница 5: ...1 2 3 5 6 7 8 9 4 10 ...

Страница 6: ...1 2 D B C A2 A1 A3 2 1 2 1 100 0 ...

Страница 7: ...F E G 1 2 2 3 1 2 1 3 ...

Страница 8: ...otection VIBRATION INFORMATION Vibration emission value ah 0 74 m s2 Uncertainty K 1 5 m s The declared vibration total value and the declared noise emission value have been measured in accordance with a standard test method and may be used for comparing one tool with another The declared vibration total value and the declared noise emission value may also be used in a preliminary assessment of ex...

Страница 9: ...ge battery after work And store it in a shade and dry place STORAGE AND MAINTENANCE OF THE MACHINE Before maintenance please switch off and take off the battery pack After each use rotate manually the drum and remove the waterproof plug Erect tools with head down so that liquid will drain out and reinstall the waterproof plug Do remember to take off the wrench in case of tossing out next time Plea...

Страница 10: ...xible shaft willworks stayinthe current position PushtheR Lpusherinturnandstartthe machine Repeat observe untilitwrapsrubbish FollowFig G Startthemachinetoretract the flexible shaft orpullout it byhand Theflexibleshaftgottwisted together Releasetheon offswitchtostoprotation Pushthelevertomiddle O F O R avoid twistingtighter AdjusttheR Lpushertoreversethedirectionofrotation a WhenforwardrotationL R...

Страница 11: ... auger Function Cleaning pipe Complies with the following Directives 2006 42 EC 2014 30 EU 2011 65 EU EU 2015 863 Standards conform to EN 62841 1 EN 62841 2 21 EN 55014 1 EN 55014 2 The person authorized to compile the technical file Name Marcel Filz Address Positec Germany GmbH Grüner Weg 10 50825 Cologne Germany 2021 02 01 Allen Ding Deputy Chief Engineer Testing Certification Positec Technology...

Страница 12: ...esignation of machinery representative of drain auger Function Cleaning pipe Complies with the following Directives Supply of Machinery Safety Regulations 2008 Electromagnetic Compatibility Regulations 2016 The Restriction of the Use of Certain Hazardous Substances in Electrical and Electronic Equipment Regulations Standards conform to BS EN 62841 1 BS EN 62841 2 21 BS EN 55014 1 BS EN 55014 2 The...

Отзывы: