6-13
ReInitAll
Parameters:
none
Function:
Instructs all attached terminals to re-initialize.
OutputRaw
Parameters:
data
Function:
This allows you to override all of WD802Term’s
Input methods (or any other method, for that matter)
and send whatever data you want to the Active
Terminal. This is most useful for adapting old DLL-
based code to use the new ActiveX system.
MapTermID
Parameters:
TermNumber
Function:
Returns the actual terminal ID letter code for a
given terminal number. Use the returned character
to match with the Terminal ID programmed into a
non-802 RF Terminal. This is provided for
backwards compatibility and should not be used for
new host applications.
GetIPAddress
Parameters:
TermNumber
Function:
Returns the actual IP address of the terminal
associated with a given ID code.
GetErrCode
Parameters:
none
Function:
Returns code for the most recent error. Calling this
method resets the Error Code to 0.
Error Codes
0. No Error
1. Command Data Too Long
2. Error on Close Device
3. Serial Out Data Too Long
4. Invalid Terminal ID On Last Command
5. Terminal ID Format Error
Содержание 802 RF