SPEAKER SETTINGS
5
LASER SETTINGS
6
LCD SETTINGS
7
OTHER SETTINGS
8
SYSTEM TOOLS
9
DONE/EXIT
0
Select the option you want to set or verify or press 0 or the F1 key to exit back to the
MODE MENU.
The groups in the keypad Setup Menu contain the following setup parameters:
Setup Group
Parameter
Setup Group
Parameter
RF Setup
RF Channel
Speaker
Beep Volume
1
Terminal ID
5
Beep Tone
Security Code
Voice Volume
Skip opening screens
Keypad Tone
Control Keys Only
Laser
Double Decode
Auto Check Back
6
4.5 Second Laserbeam
Bar Codes
Code 3 of 9
Aiming Dot Duration
2
UPC-A, EAN 13
LCD
4 Line Legacy Mode
UPC-E, EAN 8
7
6 Line Legacy Mode
Code 128
Background Color
2 of 5 Codes
Text Color
Codabar
Brightness
MSI/ Plessey
Brightness Timeout
Code 93 / Code 11
Other
Preamble
Databar / RSS / Other
8
Postamble
RS-232
Baud Rate
Characters
3
Parity
Control Keys
Data Bits
XON/XOFF Printer
Date/Time
Set Time
4
Set Date
Date Format
Year Output
Shut Down Time
Once you have selected a group to edit, you will see each parameter displayed in the order listed above. Use
the next section of this chapter as a reference for all RF Terminal Setup Parameters.
RF Configuration
Default settings are shown in
bold
type.
The RF Terminal will typically require no setup changes except, Terminal ID (if more than one terminal) and enabling
bar codes to be read other than UPC or Code 39.
RF Terminal ID
Default ID
0
Available IDs
0-9, A-Z,
a-z, - =
•
Every terminal needs a unique
Terminal ID
. The default
Terminal ID
is always shipped as
0
. If you
have more than one RF Terminal assigned to a Base Station, you must be sure that each RF Terminal has
a unique
Terminal ID
, (otherwise you will have big troubles including false error messages). The
Terminal ID
is always displayed on the Start Up screen when you power up the terminal. There are 64
Terminal IDs
available -
0-9
,
A-Z, a-z,
and the special characters "-" and "=". To change the