UrEtHANE foAM cLEANiNg : Remove the element, wash and clean the
urethane foam in kerosene. Saturate in a mixture of 3 parts kerosene and
1 part engine oil, and then squeeze to remove excess oil and put it back to
the air filter.
Fire forbidden.
10.3. cLEANiNg ANd AdJUstiNg spArk pLUg
1. If the plug is contaminated with carbon,
remove it using a plug cleaner or wire brush.
2. Adjust the electrode gap between 0.6 and 0.7 mm.
Gap 0,6 to 0,7 mm
BOUGIE
cHALLENgEr 3000
NGK BR-6HS
cHALLENgEr 4000
cHALLENgEr 5000
cHALLENgEr 7000
10.4. cLEANiNg fUEL strAiNEr
Dirt and water in the fuel are removed by the fuel strainer:
1. Remove the strainer cup and throw away water and dirt.
2. Clean the screen and strainer cup with gasoline.
3. Tightly fasten the cup to main body, making sure to avoid