background image

600LA  PARTS  LIST

NO.

PART  NAME

DESCRIPTION

QTY.

1

Control    Transformer

9645

2

2

Control    Transformer

4114

1

3

Control    Transformer

5719

1

4

Main  PCB

WNLT-01

1

5

HF  PCB

TMD-45A89

1

6

PWM  PCB

WAPD-01

1

7

PWM  PCB

WAPD-02

1

8

Relay

HR710-2PB  DC24V

1

9

Relay

LY2

1

10

Relay  PCB

WAPO-01

1

11

FUSE

5A

1

12

MF  Condensor

30

/800V

4

13

MF  Condensor

10

/800V

2

14

Condensor

3300UF/400V

2

15

Input  Terminal

6M/M

1

16

NFB

3P-80A  NDB3-100J4  80/3LTS

1

17

Front  PCB

500LT3-VR

1

18

Front  PCB

500LT3-LED

1

19

META  PCB

META  V1

1

20

VOLUME

RV24YN,  500K

2

21

Selector    Switch

XK5378

1

22

FAN

120T

2

23

FAN

150T

1

24

Terminal

MJ-175

1

25

Toggle  Switch

DWT-6210

1

26

InputDiode

6RI  100E-080

1

27

IGBT

200A/600V

2

28

IGBT  Drive  PCB

WGE-01(2K10

Ω

)

2

29

IGBT  Drive  PCB

WGE-01(10K6.8

Ω

)

2

30

TIG  IGBT    Snubber

WSB-01

1

31

Temp.  Switch

N85

1

32

Pressure    Sensor

DP-07

1

33

Solenoid  Valve

DC24V,  3.0

Φ

1

34

IGBT

200A/1200V

2

35

OutputDiode

300A/600V

4

36

Resistor,    Discharge

20W10

Ω

4

37

Resistor,    Discharge

20W50

Ω

1

38

Terminal,MID

MID

2

39

Connector

K25-2R 

2

40

Nipple

9/16*  6

Φ

2

41

Nipple

9/16*1/4

2

42

Noise  Filter    PCB

WTF-02

1

43

Surge  PCB

WBP-03

1

44

Remote  PCB

WRM-01

1

45

Induction  coil

600LA

1

46

Choke    Transformer

600LA

1

47

Main    Transformer

600LA

1

48

Resistor,    Stick

200W100

Ω

1

Содержание longrun 350LA

Страница 1: ...INVERTER AC DC TIG WELDER 350LA 500LA 600LA OPERATION MANUAL DO NOT INSTALL OPERATE OR MAINTAIN THIS MACHINE WITHOUT READING THIS MANUAL AND PLEASE ALWAYS THINK BEFORE YOU ACT www worldwel com...

Страница 2: ...00 400 Input Capacity 380V KVA 13 5 7 3 21 7 15 9 25 9 17 8 No Load Voltage V 60 380V 62 380V 60 380V Output Current Range A 10 350 20 200 15 500 20 340 15 600 20 400 Output Voltage rated output V 24...

Страница 3: ...of contact with the work or ground and watch for fire Turn off input power using the disconnect switch at the fuse box before working on the equipment Frequently inspect input power cord for damage o...

Страница 4: ...s or other alternate circuits This can create fire hazards or overheat lifting chains or cables until they fail INSTALLATION The welding machine shall be installed at a place free from the inflammable...

Страница 5: ...moving top cover 220V 380V 440V Output Connection Front of the machine Connect the work cable which is connected to the work clamp to the METAL terminal To connect the TIG torch connect a electrode ca...

Страница 6: ...COOLING Output connection for stick welding Connect the work cable which is connected to the work clamp to the TORCH terminal Connect the electrode cable which is connected to the electrode holder to...

Страница 7: ...ne will not supply power at the output If over heating occurs it will blinking on until the machine has sufficiently cooled by cooling fan or water If the output is disabled by any electrical problems...

Страница 8: ...heat affected zone fewer deformations and reduced chance of cracking and gas entrapment 16 Crater current control It controls the crater current It is important to get the good welding quality 17 Dow...

Страница 9: ...p and ready lamp are On and the cooling fan is running Select AC TIG or DC TIG from AC TIG DC TIG selection switch Start to weld with adjusting the proper welding current Adjust properly the pulse fre...

Страница 10: ...ease the torch switch the arc is off and flow the gas during the after flow time Crater Repeat Press and hold the torch switch the machine will open the gas valve to start the flow of the shielding ga...

Страница 11: ...oke down Reconnect Torch switch connector Replace Torch Replace Control PCB Gas flows continuous at Off position of GAS CHECK switch GAS CHECK switch broke down Torch broke down Control PCB broke down...

Страница 12: ......

Страница 13: ......

Страница 14: ...E RV24YN 500K 2 22 Selector Switch XK5378 1 23 FAN UF12A23STH M5 120T 2 24 FAN UF15P23BTH M5 150T 1 25 Terminal MJ 175 1 26 Toggle Switch DWT 6210 1 27 InputDiode 6RI 100E 080 1 28 IGBT 200A 600V 2 29...

Страница 15: ......

Страница 16: ......