AUDEMAT FM Probe 1.2.x User Manual
–
07/2021
Page 28
WorldCast Systems SAS - 20, avenue Neil Armstrong
–
33700 Merignac
–
Bordeaux Métropole (France)
+33 (0)5 57 928 928
–
–
www.worldcastsystems.com
4-
Real time readings of the following parameters:
•
RF, MPX, MPX Power, Pilot, RDS, Aux, L&R audio levels
•
RDS data: PI, TA, TP, PTY and radiotext
•
Watermark ID and timestamp (option)
•
RF, MPX and audio spectrums
To be compliant with the standard, the
MXP power
is taken over a rolling 1 minute window, which is only
possible with receivers continuously monitoring a single station.
Spectrums can be viewed full screen when clicking the button
.
!
When a single receiver monitors several stations, it will be locked on each station for a user set time
before moving to the next one (5 seconds per channel by default, see section 6.4.5). With less than a
minute, the displayed MPX power value is erroneous.
5-
Event log, showing the events of the last week 7 days.