G
lobal
GX
Series Hand Dryer
Owner’s Manual
Instructions apply to the following models:
GX1, GX1-M
5-5/8
(143mm)
G
lobal
Series Surface Mount
RECOMMENDED MOUNTING HEIGHTS
FROM BOTTOM OF DRYER TO FINISHED FLOOR
Men
Women
Children
Disabled
All Hand Dryers (Standard)
44”
42”
32”- 42”
36”
(Metric)
112cm
107cm
81-107cm
91cm
P
arts
L
ist
ITEM
PART NO. DESCRIPTION
1
GXT202
COVER, WHITE ABS*
2
GXT202-M
COVER, WHITE STEEL*
3
GX212-A
VENT ASS’Y W/LENS AND FOAM GASKET
4
GX216
MOTOR, 110-120V
5
GX218
HEATING ELEMENT 110-120V (GX1)
6
GX228
BLOWER WHEEL
7
GX239
SENSOR COMPLETE 110-240 VOLT
8
GB232
TAMPER-PROOF SCREWS & SECURITY WRENCH
* Must specify complete model number
E
xploded
V
iew
Installation Instructions
1. Remove cover by removing (2) tamper-proof screws using security wrench
supplied. Pull cover directly toward you.
IMPORTANT
:
S
ave
S
ecurity
W
rench
.
2. Dryers should be placed at least 2 feet (61cm) apart and at least 12” (30cm)
from washbasin. Do not install dryer over washbasin. Dryers should be at
least 18” (46cm) above any projection which may interfere with the operation
of the automatic sensor.
Hold the backplate to the wall at the suggested
MAXIMUM
mounting height.
Measure from bottom edge of the
backplate
to the
floor.
3. Mark the locations of the four mounting holes and the conduit entrance
location on the wall. (The conduit entrance is the proper hole diameter for
1/2 inch (13mm) conduit.)
4. Fasten the backplate to the wall where previously marked.
RECOMMENDATION:
Wood wall –
No. 14 (M6) wood screws, 2-3/4” (70mm) long
Cement or brick –
1/4” (M6) stud expansion bolts, 3” (76mm) long
Hollow wall –
1/4” (M6) toggle bolts, length depends on wall thickness
5. Run a single phase 120V or 230V 50/60Hz electrical service wire to the dryer
location using either the in-wall or bottom surface 1/2”conduit entrance and
connect to the lead wires as shown on the dryer schematic. The ground wire
must be connected to the dryer ground screw. IMPORTANT: All units must
be supplied with 3 wire service. Use No. 12 or 14 wire as required by local
electrical rules. Unit must be installed with separate disconnect means by a
qualified licensed electrician.
CONNECT TO A DEDICATED CIRCUIT NOT TO EXCEED 20 AMPS.
Dryers located in shower rooms or other wet locations should be equipped
with ground fault interrupter(s).
6.
Carefully
replace the cover using (2) tamper-proof screws supplied. Apply a
bead of caulk around edges of cover to wall.
WARNING: Disconnect Power Before Servicing
WARNING: For Indoor Use Only.
WARNING: Do NOT modify the product in ANY way
Modifications including cutting holes may cause damage to the unit and will VOID the warranty
WARNING: Installation Shall be Performed by a Qualified Licensed Electrician
4
1
2
6
7
3
8
10 18 " 258mm Max.
9 38 " 238mm Max.
7
8 " 22mm
Conduit Entrance
8 3
16 " 208mm
9
16 " 15mm Max.
9
16 " 15mm Max.
8 15
16 " 228mm
1 12 " 38mm
15
16 " 24mm
Mounting Holes for
1/4" [M6] screws
Template is for all
American Dryer
EXTREMEAIR, ADVANTAGE
AND GLOBAL Series dryers
Outer perimeter
of ABS Cover
Revised 10/06/2014
Mounting Diagram
5