4
CAUTION
(1) Unspecified use
Do not use the pump for purposes other than those specified on the nameplate. Specially, verify the
motor specification (phase, voltage and frequency) and connect the motor. Unspecified use could
cause personal injuries or damage to the pump and peripheral equipments.
(2) User restrictions
Transportation, installation, wiring, operation, servicing, and inspection of the pump should be
performed only by experts who have full knowledge of the handling the pump.
(3) Opening the package
Before opening the package, check the package upside down. When opening a wooden crate or box,
be careful of injury from nails and silvers.
(4) Repair and returning of the pump
In the event of a pump failure, contact the distributor or us. When the pump is to be returned by
courier, wash the interior and exterior of the pump thoroughly and verify no chemical liquid on.
Wrapping the pump in plastic bags and packing is required.
(5) Regarding resin parts
The pump is made of resin. If it is subject to impact, it could cause injury and damaged. Do not hit
objects nor got on top of the pump.
It also should be attached the piping support not to apply too much load to the pump directly.
The pump is constructed by general-purpose plastic and the pressure capacity is depending on the
temperature unlike the metal pump. Check the acceptable pressure carefully when using the pump in
the high temperature.
Pump component parts: Carbon fiber reinforced polypropylene / Alumina ceramics / CFR PTFE
O-rings: FPM (Fluorine-rubber)
Use the pump with the liquid which can be used for the above material.
The chemical resistance is greatly affected by the used liquid’s kind, concentration, temperature,
interaction of several liquid, material stress, wetted time or other conditions by itself or with others. For
this reason, we are not responsible for the chemical resistance and recommend the chemical
resistance is tested as ahead of time as possible before using.
It sure is the aged deterioration happens for the installed environment. For the pump’s long life, it is
recommended to do daily inspection and strive for the early reaction including parts replacement.