INSTALLATION
Warning
Install Ground Fault Interrupter to prevent the electrical shock!
Connect Ground line of the plug!
・
When installing the pump, move up and down the pump with a rope.
Do not use the power supply code to move the pump. It could cause electrical leaks.
・
Install the pump at the site without slurry. When the suction inlet is clogged by slurry, it could
cause the pump failure.
・
Verify the liquid level is 100mm (4in) and more when starting the pump. If not, it could cause dry
running and the pump damaged.
Move up and down the pump
with the accessary rope.
Do not move the pump with
the power supply code.
(The rope material: PP)
The power supply code
hole
Do not remove the
power supply code from
the hole.
The lowest operational
liquid level.
100mm
(4in)
400mm
(15.7in)
The lowest liquid
level at the continuous
operation.
Check that the liquid
level is 100 mm and
more at the start of
the pump.
Do not cover the
suction inlet with
slurry.