11
WGG-800
www.servotool.eu
0203-5142281
GB
1800-719901
IRL
AFTER SALES SUPPORT
WGG-800
www.servotool.eu
0203-5142281
GB
1800-719901
IRL
AFTER SALES SUPPORT
4
Instructions
Starting the generator
Fig. 1 + 3 + 4
1. Turn on fuel tap (8).
2. Turn on engine switch (5).
3. Move choke lever (6) to closed position (to restart a warm engine, leave the choke
lever in open or half-open position).
4. Pull slowly on the starter cord until it engages, then pull sharply to start the
engine (7).
5. Allow the engine to run until it warms up, and then move the choke lever to the
open position (6).
Using the AC Output (230 V)
•
Start the generator.
•
Plug in the electrical appliance plug.
Stopping the generator
Fig. 1 + 4
1. Unplug all cords (5)
2. Turn engine switch to “OFF” (5)
3. Turn off the fuel tap (8)
Using the DC Output (12V)
Fig. 5
•
Plug the charging lead into the DC output
•
Start the generator
•
Connect the red clamp to the + terminal of the battery
•
Connect the black clamp to the – terminal of the battery
Periodic maintenance
Daily (pre-operation check)
•
Check fuel hose for cracks or other damage. Replace if necessary.
•
Check exhaust-system for leakage. Retighten or replace gasket if necessary.
•
Check choke operation.
•
Check recoil starter operation.
3 Months or 50 hrs
•
Check condition of spark plug. Adjust gap and clean. Replace if necessary.
PGM6003 Ma EN-IRL 1202-15.indd 11
2/15/12 9:35 AM