Workzone GT-DC-02 Скачать руководство пользователя страница 6

10 

11 

AFTER SALES SUPPORT

      0800 / 328 6020   [email protected] 

 

 00800 / 4467 5888  

  

GT-DC-02, 02/13, E45316

AFTER SALES SUPPORT

      0800 / 328 6020   [email protected] 

 

 00800 / 4467 5888  

  

GT-DC-02, 02/13, E45316

•   Avoid contact with eyes or skin.  Immediately rinse areas 

affected by the battery acid with plenty of clean water and seek 
medical advice. 

•   Remove the batteries from the device in the case of longer  

periods of disuse.

  Battery disposal

•   Batteries and rechargeable batteries are not permitted to be 

disposed of with household waste!

•   Every consumer is legally obligated to submit batteries and 

rechargeable batteries to the collection centre of his local  
authority, district or to retailers. All batteries and rechargeable 
batteries can thereby be disposed of in an environmentally 
friendly manner.

Batteries and rechargeable batteries containing harmful 
substances are identified with this symbol and with 
chemical symbols (Cd for cadmium, Hg for mercury, Pb 
for lead).

Fault rectification

Fault

Flashing display
No display

Frozen or flashing 
display

Possible cause

Low voltage
1. Low voltage
2.  Loose connection
Random fault in 
the circuit

Solution

Replace batteries
1. Replace batteries
2. Readjust battery
Remove battery 
and reinsert again 
after one minute

CAUTION:
In the event of an electrostatic discharge on the housing, the
display can reset or an incorrect value can be displayed. In this
case, the measurement must be repeated. For this, switch the
device off and on once and carry out the zeroing by pressing the
zero gauge (ZERO) key.

Содержание GT-DC-02

Страница 1: ...IRE AFTER SALES SUPPORT info dariolondon com 00800 4467 5888 GB 0800 328 6020 MODEL GT DC 02 02 13 E45316 DIGITAL CALIPERGAUGE MANUAL ...

Страница 2: ... μA Measurement speed 1 5 m s Operating temperature 0 40 C Relative humidity 80 Storage temperature 10 C 60 C As our products are constantly being further developed and improved design and technical changes are possible Table of contents 03 Scope of delivery 03 Technical data 04 Assembly diagram 05 Safety instructions 06 Functions 06 Maintenance Storage 07 Use 08 Insertion of the battery 09 Instru...

Страница 3: ...l OFF ZERO mm inch ON mm 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Safety instructions Injury hazard The measuring edges are sharp and pointed Therefore only hold the measuring device on the handles Do not let children play with the measuring device They can injure themselves on the sharp measuring edges or swallow the battery battery compartment lid Measure very carefully on sensitive surfaces in order to...

Страница 4: ...e from watery liquid 2 Only clean with a dry cloth and some cleaning oil do not use any water solvent or abrasive detergent 3 Remove the battery if the instrument is not being used for a longer period of time 4 Preferably store the caliper gauge in the case in order to provide optimum protection Use 1 Preparation 1 Wipe of the surface of the measuring scale and clean the measuring surfaces 2 Loose...

Страница 5: ...he voltage is low due to being stored for too long please contact the supplier Note 1 After inserting the battery the caliper gauge requires several seconds approx 5 6 seconds in order to set itself The caliper gauge can only be switched on again after the end of the setting process 2 Reset the zero point of the measurement after replacing the battery Instructions for batteries Never attempt to re...

Страница 6: ...ct or to retailers All batteries and rechargeable batteries can thereby be disposed of in an environmentally friendly manner Batteries and rechargeable batteries containing harmful substances are identified with this symbol and with chemical symbols Cd for cadmium Hg for mercury Pb for lead Fault rectification Fault Flashing display No display Frozen or flashing display Possible cause Low voltage ...

Страница 7: ...cise measurements It simplifies the precise setting of the caliper gauge Support table Practical support table for cutting threads also see the back of the caliper gauge Column 1 Screw size Column 2 Thread pitch Column 3 Min drill hole diameter Column 4 Matching standard drill size Metr ISO Nenn Screw ext extr Ø mm Stg Thread Pas Paso mm Kern Hole int núcleo Ø mm Bohr Drill mèche broca Ø mm 3 0 5 ...

Страница 8: ...he battery beforehand and dispose of it properly in a collection container for batteries The packaging materials are also raw materials Therefore submit them for recycling Your responsible local authority will inform you about addresses and opening times of collection centres Conformity declaration The conformity of the product with the prescribed standards is guaranteed The complete conformity de...

Страница 9: ... fault must be returned once you have contacted the service centre by phone A new appliance will be returned This warranty is in addition to your statutory rights Your statutory rights are not affected This warranty does not apply in cases of damage caused by accident improper use abuse and force majeure This warranty will be invalidated if the appliance is tampered with in any way whatsoever For ...

Страница 10: ...____ Date of purchase ___________________________________ We recommend you keep the receipt with this warranty card Location of purchase_________________________________ Description of malfunction Return your completed warranty card to UK Ireland Dario London Service Centre PO BOX 1125 Bromley BR1 9TW UK UK 0800 328 6020 Ireland 00800 4467 5888 info dariolondon com YEAR WARRANTY 3 IRE AFTER SALES ...

Страница 11: ......