AFTER SALES SUPPORT
USA
USA
High Pressure Washer
1800 505 8311
12
TROUBLE SHOOTING:
Trouble Shooting
Problem Causes Solution
Appliance doesn’t work
Appliance doesn’t reach
operational pressure
The pump leaks
No water flows or flow
rate too low
1. No power or condition in
the socket is not working
properly.
2. The connector cable is
damaged.
1. The double nozzle is
worn cut.
2. Air exists in the hose.
3. Dirt exists in the water
storage.
4. The inlet hose leaks or
blockage.
5. The inlet or outlet value
is damaged.
6. The sealed ring of the
plunger is damaged.
7. The O-ring of the unload
valve is damaged.
8. Pump seat leaks.
1. The sealed ring is
damaged.
2. The bolt work loose.
1. The new pump doesn’t
take in water.
2. Dirt exists in the pump.
3. The inlet or outlet valve is
damaged.
1. Switch on, and open the
gun trigger valve, then fill
water into the inlet hose
so as to exhaust air,
place the inlet hose into
water tank.
2. Remove the dirt.
3. Change the valve.
1. Change the sealed ring.
2. Tighten the bolt.
1. Change the double
nozzle.
2. Start the motor, turn on
the spray nozzle and fill
the inlet hose with water
to exhaust air.
3. Clean or Change the inlet
hose.
4. Change the valves.
5. Change the sealed ring.
6. Change the O-ring.
7. change the pump seat.
1. Check the power source
and the socket to see
if the plug connected.
2. Change the cable.
If any problems are encountered that are not covered above, refer to qualified service
personnel.
WARNING:
To reduce the risk of electrocution, keep all connections
dry and off the ground. Do not touch plug with wet hands.
6. Maintenance
6.1 Monthly or as required, maintenance the appliance.
6.1.1
Clean the nozzle. Remove dirt from the nozzle hole with a needle and
rinse it with water from the front.
6.1.2
Clean the strainer in the water connection. It can e easily removed
with flat-nosed pliers.
6.2 Winter protection
Frost will destroy an appliance that has not been completely emptied of
water. The correct method is to separate the inlet hose from the water
supply system. Turn on the cleaner to run for about 30 seconds for water
extraction. Remove the high-pressure plastic hose to exhaust the remain-
ing water in it. The appliance had better be stored in a warm room.