4. GENERAL DEVICE INFORMATION

In both versions, there is an RS485 bus connector. You can use the same commands as on USB 4.1.2. BAUDRATE
is 9600.

4.1.2 USB Communica on

A USB-C cable can be used to set the parameters of the Workswell BB200 on versions 1.4.17 and above. Connect
the device to the computer with a USB-C cable. The device must be connected to the power supply at all mes,
connec ng only to the USB-C without supplying power to the device will not suffice and you will not be able to
communicate with the device. A er connec ng to the PC and installing the driver, the device will show up as a
virtual COM port named USB-SERIAL CH340. Set this port in Pu y, CMD or other. Set BAUDRATE to 115200. In
the serial line se ngs, set 8 data bits, 1 stop bit, and no parity bit (8N1).

4.1.3 Command protocol

Communica on using ASCII characters.
List of commands for communica on with the device:

SET C/F <NNN.N>

set setpoint to <NNN.N> °C/°F temperature

SET C/F ?

shows current setpoint

GET C/F ?

shows current temperature

GET IN C/F ?

shows current temperature of the electronics

DISP C/F

switches the temperature shown on the display to °C or °F

LOCK ?

locks the temperature

UNLOCK ?

unlocks the temperature

ARTICLE ?

shows ar cle number

SERIAL ?

shows serial number

VERSION ?

shows FW version number

BUZZER ON

turns on the buzzer

BUZZER OFF

turns of the buzzer

LED <NNN>

sets the LED intensity as a percentage of 0 -100 %, where 0 does

not light up the LED at all

LED ?

shows current LED intensity

Note:

Commands listed above can be used with °C or °F. For each C/F command choose one of the op ons.

Example:

SET C ?

shows current temperature in °C,

SET F ?

shows current temperature in °F.

E-mail and Web

[email protected]
www.workswell.eu

Mobile:

+420 725 877 063

ID:

Reg. No.: 29048575
VAT No.: CZ29048575

Headquarters

U Albrechtova vrchu 12
155 00, Prague 13
Czech Republic

Revision 1.6.2 EN, 7

th

Jun, 2021

All pictures are only for illustra on.
Real values may vary.

6

Содержание BB200 SDK

Страница 1: ...WORKSWELL BB200 SDK USER MANUAL FW Version 1 4 20 or higher Release date 7th June 2021 Revision 1 6 2 EN...

Страница 2: ...485 Communica on 5 4 1 2 USB Communica on 6 4 1 3 Command protocol 6 5 BB200 SDK Control GUI Applica on 7 5 1 Setup 7 5 2 Main Window 7 5 2 1 Connect bu on 8 5 2 1 1 Port selec on window 8 5 2 1 2 Ref...

Страница 3: ...Workswell s r o is allowed to open or modify such product Workswell s r o has no other obliga on or liability for defects than those set forth above No other warranty is expressed or implied Workswell...

Страница 4: ...nstalled or put into opera on Any interference and non cer ed service opera ons on the product leads to an automa c loss of warranty Warning The device generates a large amount of heat and its parts c...

Страница 5: ...t you may encounter can be found within this manual In case you have further ques ons either Contact your authorized dealer or Contact our technical support at support workswell eu E mail and Web info...

Страница 6: ...on it is necessary to connect AB4_485rs with YZ_rs485 and AB_485rs with YZ_rs48 Figure 4 1 Scheme for 1 x x version full duplex For 2 x x versions the pin AB_485rs is connected to YZ_rs485 and AB_485r...

Страница 7: ...ommunica on with the device SET C F NNN N set setpoint to NNN N C F temperature SET C F shows current setpoint GET C F shows current temperature GET IN C F shows current temperature of the electronics...

Страница 8: ...a ached installer A er the installa on you may need to install CH320 driver using provided le CH34xInstall_Windows_v3_4 You may also need to install Microso Visual C Redistributables if it was not in...

Страница 9: ...list of available ports both USB C and RS485 A er choosing and con rming the corresponding port the program will a empt the connec on to the BB200 device Figure 5 2 Port selec on window 5 2 1 2 Refre...

Страница 10: ...indow 5 2 2 Upload Firmware bu on This func on is working only on Windows If you wish to update your rmware contact our support at support workswell eu E mail and Web info workswell eu www workswell e...

Страница 11: ...asic info about the product E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29048575 Headquarters U Albrechtova vrchu 12 155 00 Prague 13 Czech Rep...

Страница 12: ...BB200 can be locked or unlocked using a switch When the BB200 is locked the setpoint temperature change is not allowed 5 2 7 Buzzer The Buzzer can be enabled or disabled using a switch E mail and Web...

Страница 13: ...e BB200 Last 10 commands and answers are shown in a log E mail and Web info workswell eu www workswell eu Mobile 420 725 877 063 ID Reg No 29048575 VAT No CZ29048575 Headquarters U Albrechtova vrchu 1...

Страница 14: ...mail sales workswell eu Headquarters Workswell s r o U Albrechtova vrchu 12 155 00 Prague 13 Czech Republic Partners Worldwide Visit our partner list online Company contact details Mobile 420 725 877...

Отзывы: