WorkPro LS-Node Series Скачать руководство пользователя страница 1

1

LS-

Node

March 2019

LS-

Node

Содержание LS-Node Series

Страница 1: ...1 LS Node March 2019 LS Node...

Страница 2: ...nge includes three different models LS Node1 LS Node2 and LS Node4 These multiprotocol RDM DMX streaming devices are fully compatible with any lighting control or device that supports ArtNet or sACN s...

Страница 3: ...ANUALS OR PRODUCTS THE SPECIFICATIONS AND INFORMATION CONTAINED IN THIS MANUAL ARE FOR INFORMATIONAL PURPOSES ONLY AND ARE SUBJECT TO CHANGE AT ANY TIME WITHOUT NOTICE AND MAY NOT BE USED AS A COMMITM...

Страница 4: ...1 3 Box content 1 4 Product overview 2 Configuration and Operation 2 1 Accesing the WebServer 2 2 Port configuration 2 3 Setting ports as output 2 4 Setting ports as input 3 Updating Reset 3 1 Firmwar...

Страница 5: ...the power supply supplied in the box Install the device in a flat and stable location This product is rated IP20 so do not install near water or wetness it is for indoor use only Place the device away...

Страница 6: ...multiprotocol supporting industry standards ArtNet and sACN LS Node is fully compatible with LightShark consoles and can also be configured via a internal webserver allowing users to configure paramet...

Страница 7: ...PE C 5v 2A POE POWER RESET 7 LS Node 1 4 Product Overview DMX OUT DMX IN DMX 1 OUT DMX 1 IN DMX 2 OUT DMX 2 IN DMX 1 IN OUT DMX 2 IN OUT DMX 3 IN OUT DMX 4 IN OUT LS Node 1 Front view Rear View LS Nod...

Страница 8: ...B port unlike the A port allows you to power the Node through P o E 5 Power LED which is illuminated when the Node is connected to the USB C power or to a P o E switch 6 Reset switch allows you to ret...

Страница 9: ...9 LS Node Product Dimensions mm mm mm mm...

Страница 10: ...let from which you want to connect must be in the same subnet as the nodes NOTE The use of Safari FireFox or Chrome web browsers is recommended NOTE If you use iOS devices the minimum software version...

Страница 11: ...to select between each of the different ports Note that depending on the LS Node model selected you will have access to more or less ports 2 ENABLE allows you to enable or disable each port independen...

Страница 12: ...echnology Association and its first official release was ANSI Standard E1 17 2006 Entertainment Technology Architecture for Control Networks The standard was subsequently revised and published as ANSI...

Страница 13: ...s output the LS Node will convert the ArtNet or ACN information received on the network ports to DMX via the XLR 5 output ports It is possible to configure the output mode MODE as SINGLE or as MERGER...

Страница 14: ...controlling the same equipment with two different DMX controllers LTP In this mode two universes will be merged into one using the LTP Latest Takes Preference priority forwarding universe A UNIVERSE o...

Страница 15: ...the LS Node will convert DMX information received on XLR 5 input ports to Art Net or ACN via Ethernet ports It is possible to configure the output mode MODE as NORMAL or as BACKUP In this mode the LS...

Страница 16: ...port If the signal returns the LS Node will switch automatically again as soon as the first DMX frame is received Through UNIVERSE you can define the ArtNet ACN universe to which the DMX signal receiv...

Страница 17: ...can be found on the WorkPro website Please download it and click on the SELECT FILE button you will be shown the file browser where you should select the downloaded firmware Then press the UPLOAD FIL...

Страница 18: ...le to restore the LS Node to its original factory state 1 Connect the LS Node 2 Keep the reset button pressed for 5 seconds 3 Release the button The device will restart by loading the default values A...

Страница 19: ...e you need assistance If you are in Spain please contact Equipson S A If you are in any other country please contact your local distributor CONTACT Equipson SA Poligono industrial L Alter Silla Spain...

Отзывы: