![Workhorse ALLISON 1000MH Скачать руководство пользователя страница 220](http://html1.mh-extra.com/html/workhorse/allison-1000mh/allison-1000mh_service-manual_997070220.webp)
WORKHORSE CUSTOM CHASSIS
Service Manual
2007 W Series
SECTION
7.2
PAGE
220
Automatic Transmission – Allison
2007 W Series Chassis
© 2006 Workhorse Custom Chassis — All Rights Reserved
WSM082106
– Poor terminal tension
– A chafed wire
– A broken wire inside the insulation
• When diagnosing for an intermittent short or open,
massage the wiring harness while watching the test
equipment for a change.
• You may have to drive the vehicle in order to experience
a condition.
Test Description
The numbers below refer to the step numbers on the
diagnostic table.
2. This step tests for TCC application at startup, stuck on.
3. This step inspects for internal damage.
4. This step inspects for 3 possible causes for the TCC
being stuck on.
DTC P0742
Step
Action
Yes
No
Schematic Reference: Automatic Transmission Controls Schematics
1
Did you perform the Diagnostic System Check – Vehicle?
Go to Step 2
Go to Diagnostic
System Check - Vehicle