background image

 

6

 

General notes

 

6 720 610 577 GB (01.07)

 

1

General notes

 

To get the best from your appliance please read these instruc-
tions carefully.

 

Sealed heating systems

 

The appliance is fitted to a sealed heating system which is pre-
pressurised. Your installer will tell you of the minimum and maxi-
mum pressure which must be indicated on the pressure gauge.

Check regularly that the pressure is maintained and contact your 
installer or maintenance engineer if there is a permanent signifi-
cant drop in the pressure. If the system loses pressure it should 
be repressurised and the cause of the fall investigated.

 

Central heating systems

 

During the first few hours of operation of the central heating sys-
tem, check that all radiators are being heated at an even rate. If 
the top of a radiator is at a lower temperature than the bottom then 
it should be vented by releasing air through the venting screw at 
the top of the radiator. Ask your installer to show you how this is 
done. Repeated venting will reduce the quantity of water in the 
system and this must be replenished for safe and satisfactory 
operation of the appliance.

Should water leaks be found in the system or excessive venting is 
required then a service engineer must be contacted to inspect the 
installation and rectify any fault.

Only additives that are compatible with aluminium may be used in 
the system. Any incompatible additive used will invalidate the 
guarantee.

 

Condensate drain

 

This is a condensing appliance and the terminal will, at times, give 
out a plume of water vapour. This is quite normal.
The appliance produces quantities of condense which is dis-
charged regularly through the siphon.

Содержание ZB 7-27 HE

Страница 1: ...nd Customer Care Guide Greenstar HE combi Condensing boiler Greenstar HE system Condensing boiler 6 720 610 577 00 10 ZWB 7 27 HE combi GC Number 47 311 55 ZB 7 27 HE system GC Number 41 311 49 6 720...

Страница 2: ...3 4 Controlling Central Heating 13 3 5 Combination Boilers Setting the Hot Water Temperature 14 3 6 Summer Mode Hot Water Only Combi Appliances 15 3 7 Frost protection Combi Appliances 15 3 8 Fault C...

Страница 3: ...up by Worcester Care Call a complete mainte nance scheme to keep your boiler operating at peak condition and efficiency No wonder that more and more people are agreeing that when it is gas it has to...

Страница 4: ...ors and windows y Do not operate any electrical switches y Do not smoke y Extinguish any naked flames y Call your gas company If you smell fumes from the appliance y Switch off appliance y Open window...

Страница 5: ...no potential hazard due to the appliance being electri cally unsafe y There are no substances used in the construction that are a potential hazard in relation to the COSHH Regulations Con trol of Sub...

Страница 6: ...being heated at an even rate If the top of a radiator is at a lower temperature than the bottom then it should be vented by releasing air through the venting screw at the top of the radiator Ask your...

Страница 7: ...e is fitted to all the radia tors except one usually the bathroom radiator They should con form to the requirements of BS2767 10 Showers bidets taps and mixing valves Combination Boilers Standard hot...

Страница 8: ...Installation of a scale inhibitor assembly should be in accordance with the requirements of the local water com pany An isolating valve should be fitted to allow for servicing Alternatively the maximu...

Страница 9: ...ow and return 171 Hot water 172 Gas isolation valve open 173 Cold water inlet 295 Identification sticker 310 Hot water temperature control combi 317 Display 363 Indicator lamp for burner on 364 Indica...

Страница 10: ...e with direction of flow the cock is open Central heating system valves 170 y Using a spanner turn square nut until groove is in line with direction of flow see detail Groove at right angles to direct...

Страница 11: ...nter is below 1 bar when the system is cold top up the system with water until the pointer is 1 bar Your installer will have shown you how to do this y The maximum operating pressure of 2 5 bar at max...

Страница 12: ...that the condensation trap is filled after the appliance has been installed or after the appliance has been out of use for a long period For that reason the appli ance remains at minimum heating outp...

Страница 13: ...ature heating setting E approx 75 C Max setting 88 C When the burner is lit the red indicator lamp is illuminated 3 4 Controlling Central Heating y Set room thermostat to the desired room temperature...

Страница 14: ...y pressing and holding the ECO button until the display lights you can switch between Comfort mode and Economy mode Comfort mode button is not lit factory setting The appliance is held constantly at t...

Страница 15: ...ing period before hot water is available 3 6 Summer Mode Hot Water Only Combi Appliances With room thermostat y Turn temperature control on the appliance anti clockwise as far as the stop The central...

Страница 16: ...ppliance will then start up again and the display will show the central heating flow temperature If the button does not flash y Switch the appliance off and then on again at the master switch The appl...

Страница 17: ...hermo static radiator valves The central heating control on the boiler should be set to the max imum rated temperature of the central heating system or to posi tion E when the maximum central heating...

Страница 18: ...lt in considerable energy savings For combi appliances The on demand activation using the ECO button makes possi ble the maximum savings of gas and water Now you know how to heat your home economicall...

Страница 19: ...k to hand when calling a Service Engineer 6 Maintaining your appliance Your new Worcester Greenstar gas fired appliance represents a long term investment in a reliable high quality product In order to...

Страница 20: ...request simply call our local rate number above and your request will be routed to your Regional Service Centre Region Telephone Fax Operating Hours Mon Fr Operating Hours Sat Sc Scotland 08705 256206...

Страница 21: ...lled for over 24 months OR Our Field Service Engineer finds no fault with the appliance see NOTE OR The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipme...

Страница 22: ...the first 2 year service has been carried out to the satisfaction of Worcester Heat Systems Limited when requested That any product or part thereof returned for servicing under the guarantee any comp...

Страница 23: ...vice by establishing a reference and permanent record for your boiler This will not affect your statutory rights in any way Important For your own record Model Serial number See identity label inside...

Страница 24: ...e outside temperature control unit to the appropriate setting Hot water temperature ECO button lit Economy mode ECO button not lit Comfort mode Hot water only Fault Condition If the button flashes pre...

Отзывы: