The appliance is fitted with a blanking panel or an electronic

programmer on the facia panel for the control of domestic hot water
and central heating.

OPERATING MODES

HOT WATER ONLY. 

The appliance will operate at any time

there is a demand for hot water. Heating temperature control at OFF
(fully anti-clockwise).

OFF. 

Both hot water and central heating will remain off when

the heating and hot water temperature controls are at OFF (fully anti-
clockwise).

HEATING AND HOT WATER.

Hot water will be supplied when a

demand is made. Heating and hot water temperature control at OFF
(fully anti-clockwise).

Central heating will operate continuously in response to a

demand from a room thermostat or thermostatic radiator valves if fit-
ted. 

HEATING ONLY.

Hot water temperature control at OFF (fully

anti-clockwise). The appliance will operate in response to a demand
from a room thermostat or thermostatic radiator valve, if fitted.

ELECTRONIC PROGRAMMER

Your Installer may have mounted the optional electronic pro-

grammer on the appliance facia panel. Operating instructions are sup-
plied with the programmer.

TEMPERATURE CONTROLS 

The Heating Temperature Control gives control over the temper-

ature of water supplied to the radiators when the boiler is serving the
central heating system. This control does not influence the tempera-
ture of the Hot Water which is set by the Hot Water Temperature
Control. The controls have a range as indicated in Fig. 2.

The operating temperatures may be set anywhere within the

range. With a high central heating temperature setting the radiators
will get hotter and high room temperatures will be achievable.
Similarly the temperature of the hot water can be controlled. With
lower settings the radiators and hot water will be cooler but in winter
conditions the central heating and hot water may not reach their
design temperatures.

The temperature controls will shut down the relevant operating

mode when turned fully anti-clockwise.

The Heating Temperature Control is also used to reset any safety

lock-outs by turning it OFF and ON.

WARNING:

Do not attempt to adjust any sealed components on

the appliance.

Any interference with sealed components may cause a danger-

ous condition.

OPERATION OF CON-

TROLS

Содержание Highflow 400 Electronic Series

Страница 1: ...HIGHFLOW 400 ELECTRONIC SERIES USER INSTRUCTIONS CUSTOMER CARE GUIDE G C NUMBERS APPLIANCE NATURAL GAS L P G Fanned Flue RSF 47 311 61 47 311 64 Balanced Flue BF 47 311 62 Open Flue OF 47 311 63...

Страница 2: ...Electronic appliance offers you the very best of every thing quality efficiency economical running costs proven reliability and value for money What s more you also have the assur ance of our no nons...

Страница 3: ...ating The hot water delivery rate is limited to 18 l m The specific rate declared as part of the relevant standard is 20 l m To achieve this a tank temperature of 75 C is required The appliances can o...

Страница 4: ...When a demand is made for heating by the system controls i e a programmer or room thermostat The water diverter valve will open the pump will energise circu lating primary water around the heating sys...

Страница 5: ...rly that this pressure is main tained and contact your installer or maintenance engineer if there is a permanent significant drop in pressure indicated on the gauge If the system loses pressure it sho...

Страница 6: ...ntact Worcester Heat Systems Ltd HOT AND COLD FLOW If the flow of water demanded from both hot and cold service outlets is dependent upon mains supply it may not be possible in some installations to o...

Страница 7: ...described in BS 6798 1987 CIRCULATING PUMP This may be fitted with a speed adjuster If so it will be factory set at maximum and should not be re adjusted FROST PRECAUTIONS If the appliance is not to b...

Страница 8: ...he appliance facia panel Operating instructions are sup plied with the programmer TEMPERATURE CONTROLS The Heating Temperature Control gives control over the temper ature of water supplied to the radi...

Страница 9: ...9 Fig 2 Facia panel Heating Temperature Control Minimum setting Maximum setting Optional Facia Mounted Programmer Power Light CH ON Light OFF HW ON Light Hot Water Temperature Control...

Страница 10: ...entral heating temperature control B to the required position TO STOP THE APPLI ANCE For Short Periods Set the temper ature controls or programmer to OFF as indicated by the Demand lights F G going ou...

Страница 11: ...relight automatically when the power supply is restored However depending upon circumstances it may be necessary to turn the Heating Temperature control OFF and ON before the appliance will operate I...

Страница 12: ...CHARGES All of our field service engineers are factory trained If you request a visit from an engineer and your appliance has been installed within the last 12 months no charge will be made for parts...

Страница 13: ...e it is essential that your boiler receives regular competent servicing and annual maintenance checks beyond the initial 12 month guarantee period Regular service contracts can be arranged with your i...

Страница 14: ...01506 441 687 OPERATING HOURS Mon Fri 8 00am to 6 00pm Sat 8 30am to 1 00pm Please contact our UK Call Centre number where our friendly operators will book your call with one of our team of nationwid...

Страница 15: ...ioned and where appropri ate the first 12 month service has been carried out to the satisfaction of Worcester Heat Systems Limited when requested 3 That any product or part thereof returned for servic...

Страница 16: ...this will not affect your statutory rights in any way it will assist us to maintain an effective and efficient customer service by estab lishing a reference and permanent record for your boiler IMPORT...

Отзывы: