Hot Water and Central Heating Mode:

The appliance will supply heat to the central heating system as

required. A demand for hot water at a tap or shower will override the
central heating function for the period of the domestic hot water
demand.

When domestic hot water is no longer required the burner and

pump will continue to operate until the heatbank is back to the
required temperature. 

The appliance will then return to the central heating state and

its normal mode of operation.

Similarly the hot water is occasionally diverted from the central

heating system into the heatbank to maintain the stored primary hot
water temperature. 

NOTE: 

If in doubt about the use of the controls ask your

installer to assist you. 

Central Heating Mode:

When a demand is made for heating by the system controls (i.e.

a programmer or room thermostat).

The water diverter valve will open, the pump will energise circu-

lating primary water around the heating system and the burner will
light. The appliance will operate as necessary to maintain the temper-
ature of the radiators at the level set by the adjustment of the Heating
Temperature Control. (See Fig. 2.) 

If the system no longer requires heat to maintain the desired

room temperature, the burner will extinguish. The pump will contin-

ue to run for a short period to
dissipate the residual heat from
the appliance and then switch
off. 

4

Fig. 1. System Diagram of Highflow 400 Electronic Series.

Primary
Water
circulation

Water
diverter
valve

From
radiators

Mains
cold in

Flow tur-

bine

Domestic hot
water out

Expansion
vessel

Slot in
front cover.
(O.F. only)

Pilot obser-
vation win-
dow. 

To
radiators

Circulating

pump

Heat

exchanger

Heatbank

Burner

Boiler

Содержание Highflow 400 Electronic Series

Страница 1: ...HIGHFLOW 400 ELECTRONIC SERIES USER INSTRUCTIONS CUSTOMER CARE GUIDE G C NUMBERS APPLIANCE NATURAL GAS L P G Fanned Flue RSF 47 311 61 47 311 64 Balanced Flue BF 47 311 62 Open Flue OF 47 311 63...

Страница 2: ...Electronic appliance offers you the very best of every thing quality efficiency economical running costs proven reliability and value for money What s more you also have the assur ance of our no nons...

Страница 3: ...ating The hot water delivery rate is limited to 18 l m The specific rate declared as part of the relevant standard is 20 l m To achieve this a tank temperature of 75 C is required The appliances can o...

Страница 4: ...When a demand is made for heating by the system controls i e a programmer or room thermostat The water diverter valve will open the pump will energise circu lating primary water around the heating sys...

Страница 5: ...rly that this pressure is main tained and contact your installer or maintenance engineer if there is a permanent significant drop in pressure indicated on the gauge If the system loses pressure it sho...

Страница 6: ...ntact Worcester Heat Systems Ltd HOT AND COLD FLOW If the flow of water demanded from both hot and cold service outlets is dependent upon mains supply it may not be possible in some installations to o...

Страница 7: ...described in BS 6798 1987 CIRCULATING PUMP This may be fitted with a speed adjuster If so it will be factory set at maximum and should not be re adjusted FROST PRECAUTIONS If the appliance is not to b...

Страница 8: ...he appliance facia panel Operating instructions are sup plied with the programmer TEMPERATURE CONTROLS The Heating Temperature Control gives control over the temper ature of water supplied to the radi...

Страница 9: ...9 Fig 2 Facia panel Heating Temperature Control Minimum setting Maximum setting Optional Facia Mounted Programmer Power Light CH ON Light OFF HW ON Light Hot Water Temperature Control...

Страница 10: ...entral heating temperature control B to the required position TO STOP THE APPLI ANCE For Short Periods Set the temper ature controls or programmer to OFF as indicated by the Demand lights F G going ou...

Страница 11: ...relight automatically when the power supply is restored However depending upon circumstances it may be necessary to turn the Heating Temperature control OFF and ON before the appliance will operate I...

Страница 12: ...CHARGES All of our field service engineers are factory trained If you request a visit from an engineer and your appliance has been installed within the last 12 months no charge will be made for parts...

Страница 13: ...e it is essential that your boiler receives regular competent servicing and annual maintenance checks beyond the initial 12 month guarantee period Regular service contracts can be arranged with your i...

Страница 14: ...01506 441 687 OPERATING HOURS Mon Fri 8 00am to 6 00pm Sat 8 30am to 1 00pm Please contact our UK Call Centre number where our friendly operators will book your call with one of our team of nationwid...

Страница 15: ...ioned and where appropri ate the first 12 month service has been carried out to the satisfaction of Worcester Heat Systems Limited when requested 3 That any product or part thereof returned for servic...

Страница 16: ...this will not affect your statutory rights in any way it will assist us to maintain an effective and efficient customer service by estab lishing a reference and permanent record for your boiler IMPORT...

Отзывы: