Damage caused by frost
The heating system can freeze when not in operation.
▶ Leave the heating system on if the outside temperature is below 0 °C.
▶ If the Sense I is used as a controller, system frost protection is not possible. Frost
protection can only be guaranteed where outdoor weather-compensated
controls are used.
▶ Correct any faults immediately.
2
Product details
•
Room temperature-dependent controller
for heating systems with one
unmixed heating circuit
•
Zone controller
for one unmixed heating circuit with a wiring module, and max.
4 heating circuits in systems without alternative Building Management Systems
or miscellaneous high level controls. For additional time control of the zones a
Sense II can be used instead of a Sense I (combination of 1 Sense II and a
maximum of 2 Sense I with a wiring module).
•
Room thermostat
in systems with higher-level control (e.g. Greenstar Sense II
with max. 4 heating circuits)
•
For heat sources with 2-wire BUS, e.g. EMS (Heatronic 3®) and EMS 2
•
Must be used in conjunction with a suitable compatible time control
•
The Sense I may not be used as a controller for heat sources with an external
cylinder primary pump. If an external cylinder primary pump is installed, the
Sense I may only be used as a room thermostat.
•
Use in conjunction with Worcester FX controls FR10, FW100, FR110 is not
possible.
•
Some settings may not be available, depending on the connected heat source.