![Worcester Greenstar Oilfit Flexi CF Flue Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/worcester/greenstar-oilfit-flexi-cf-flue/greenstar-oilfit-flexi-cf-flue_installation-instructions-manual_996563013.webp)
Installation
13
Greenstar Oilfit Flexi CF Flue – 6720807911 2019/05
4.4
Fitting the support bracket, seal, and adaptor
1. Slide the Chimney support bracket (2) over the flexible flue liner (1).
2. Apply silicon grease (3) to the seal (4) and fit the seal into the second
or third gap from the top of the flexible liner (1), ensure that the seal
is not twisted and is seated properly.
3. Check that the locking lugs on the adaptor assembly (5) are fully
open.
Push the adaptor (5) onto the flexible liner (1) until the liner bottoms
out.
4. Push the locking tabs in until they click into place and are locked.
Fig. 18 Terminal assembly
[1]
Flexible flue liner
[2]
Chimney support bracket
[3]
Silicon grease
[4]
Seal
[5]
Adaptor assembly
4.5
Fitting the chimney cowl
The terminal flue end must be at least 350mm long.
Ensure that the chimney bracket is larger than the chimney opening and
rests on the top of the chimney. When fitted, the Chimney cowl will hold
the flue in place.
Fig. 19 Terminal flue
[1]
Flexible flue liner
[2]
Chimney bracket
[5]
Flexible to rigid adaptor
[6]
Flue terminal end
[7]
Chimney cowl
[8]
Flue terminal grille
1. Apply silicon grease to the seal on the adaptor (5) and fit the flue
terminal (6)to the adaptor (5).
2. Fit the Chimney cowl (7) over the terminal end (6).
Mark the cowl securing points.
Turn the cowl to reveal the marked securing points, drill and fit the
wall plugs.
Secure the cowl (7) with the screws provided.
1
5
2
4.
4
1.
2.
3.
0010028890-001
3
≥ 350mm
6
0010028892-001
5
1
2