All radiators must be heated at an even rate. If the top of a radiator is at a lower temperature than the 
bottom then it should be vented by releasing air through the venting screw at the top of the radiator. 
Ask your installer to show you how this is done.

This boiler is fitted to a sealed system. Should water leaks be found or if excessive venting is required, 
then a service engineer must be contacted to inspect the installation and rectify any fault.

Only additives that are compatible with aluminium may be used in the system. Any incompatible 
additive used will invalidate the guarantee.

Pluming and Condensate drain

This is a condensing boiler and the flue terminal will, at times give out a plume of water vapour. This 
is quite normal.

The boiler produces condensate which is discharged regularly by a syphon within the boiler via a 
plastic pipe to a drain. This pipe must not be blocked or altered in any way.

Room thermostat / programmer

A room thermostat / programmer must be fitted to control the central heating. This controls the times 
and temperatures of the central heating, preventing the boiler from firing unnecessarily. Refer to the 
instructions supplied with the thermostat and programmer for further information.

Thermostatic radiator valves

Thermostatic radiator valves must be fitted in sleeping accommodation. It is recommended that this 
type of valve is fitted to all but one of the radiators. The remaining radiator, where the room thermostat 
is located, must be uncontrolled and left open.

Pump over run function

After the boiler has finished a demand for central heating or hot water, the pump continues to run for 
three minutes to dissipate the heat from within the boiler.

Pump anti-seizure

If there has been no heating demand for 24 hours the boiler will run the system pump for a few seconds 
to reduce the possibility of pump seizure during long periods of inactivity.

SEDBUK

Seasonal Efficiency of Domestic Boilers in the UK.

Содержание GREENSTAR i SYSTEM

Страница 1: ...UK IE USER MANUAL WALL HUNG RSF GAS FIRED CONDENSING SYSTEM BOILER GREENSTAR i SYSTEM 6720643356 00 1Wo FOR CENTRAL HEATING SYSTEMS 6 720 644 864a 2010 10...

Страница 2: ...orcester Bosch Group The company prides itself on manufacturing boilers to the strictest quality control standards throughout every stage of production Worcester Bosch group has led the field in innov...

Страница 3: ...1 1 Switch off the central heating 8 3 1 2 Boiler frost protection 9 3 1 3 Setting the hot water temperature 9 3 1 4 Boiler reset 10 4 System Pressure 11 4 1 Sealed heating system 11 4 2 External fill...

Страница 4: ...ossible risk to life IMPORTANT INFORMATION ADDITIONAL SYMBOLS Safety instructions in this document are framed and identified by a warning triangle which is printed on a grey background Electrical haza...

Страница 5: ...effects COMBUSTIBLE AND CORROSIVE MATERIALS Chemically aggressive substances can corrode the boiler and invalidate any warranty B Do not store or use any combustible materials paper thinners paints et...

Страница 6: ...that needs to be completed by the installer at the time of installation It confirms that the boiler has been installed and commissioned according to the manufacturers instructions The log book provide...

Страница 7: ...Boiler Controls 1 Central heating temperature control 6 ECO button non functional 2 Burner indicator Green 7 Reset button 3 Service button 8 Hot water temperature control 4 Cover or optional Programm...

Страница 8: ...The Burner indicator green will illuminate to show that the boiler is running Fig 2 Central heating temperature control 3 1 1 SWITCH OFF THE CENTRAL HEATING 1 Turn the temperature control knob to the...

Страница 9: ...eezing This process will be repeated until such time that the boiler temperature does not drop below 5 C 3 1 3 SETTING THE HOT WATER TEMPERATURE 1 Turn the hot water temperature control knob to the de...

Страница 10: ...ress the reset button for approximately five seconds When the boiler resets the reset button will no longer be illuminated 2 The mains indicator will no longer be flashing Fig 5 Reset button and mains...

Страница 11: ...sure is maintained Fig 6 Optimum pressure when cold area A B Contact your installer or maintenance engineer if a permanent significant decrease in pressure is indicated on the pressure gauge The filli...

Страница 12: ...hose and screw on hand tight to valve 3 Turn the handle screwdriver slot point 90 to open the valves 4 The handle screwdriver slot point will be in line with the valves Fig 7 External filling loop 5...

Страница 13: ...ided adequate space around the boiler for safety and servicing access Fig 8 Service clearances CAUTION Restricted space The boiler may overheat B Do not restrict this space with the addition of cupboa...

Страница 14: ...person beyond the initial 2 year guarantee period If you would like to know more about a Worcester Bosch Group service contract please tick the appropriate box on your warranty registration card If yo...

Страница 15: ...eating system B Bleed radiators and recharge heating system Desired room temperature exceeded by large amount Radiators are too hot B Turn down thermostatic radiator valves room thermostat B Reduce ce...

Страница 16: ...wed by applying a hot water bottle a microwaveable heating pack the sort used for muscular aches and pains or a cloth soaked in hot water to the exterior of the pipe close to the point of blockage Hot...

Страница 17: ...n entry in the Benchmark Checklist Our Field Service Engineer finds no fault with the boiler The cause of breakdown is misuse or with other parts of your plumbing heating system or with equipment not...

Страница 18: ...as much as possible for the central heating system The temperature of each room can be set individually except primary room with the room thermostat using the thermostatic radiator valves ROOM THERMO...

Страница 19: ...re reduced by using a suitable draught excluder CURTAINS Lined curtains or heavier full length curtains can provide excellent insulation However always ensure that the curtains do not drape over radia...

Страница 20: ...ssible technology and materials for protecting the environment taking account of economic considerations PACKAGING We participate in the recycling programmes of the countries in which our products are...

Страница 21: ...ed out to the satisfaction of Bosch Thermotechnology Ltd when requested These should be part of the Benchmark Checklist The boiler has been used only for the normal domestic purposes for which it was...

Страница 22: ...a plastic pipe to a drain This pipe must not be blocked or altered in any way Room thermostat programmer A room thermostat programmer must be fitted to control the central heating This controls the ti...

Страница 23: ...23 GLOSSARY 6 720 644 864a 2010 10...

Страница 24: ...ARES 01905 752571 LITERATURE 0844 892 9800 TRAINING 01905 752526 SALES 01905 752640 WEBSITE worcester bosch co uk Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0844 892 9900 Worcest...

Отзывы: