background image

3

Symbols and safety precautions

Greenstar FS CDi 

ErP

– 6720818078 (2015/12)

1

Symbols and safety precautions

1.1

Explanation of symbols

Warning symbols

Signal words indicate the seriousness of the hazard in terms of 
the consequences of not following the safety instructions.

NOTICE

 indicates possible damage to property or 

equipment, but where there is no risk of personal injury.

CAUTION

 indicates possible personal injury.

WARNING

 indicates possible severe personal injury.

Important information

Additional symbols

1.2

Safety precautions

If you smell gas

A gas leak could potentially cause an explosion. If you smell gas, 
observe the following rules.

▶ Prevent flames or sparks:

– Do not smoke, use a lighter or strike matches.
– Do not operate any electrical switches or unplug any 

equipment.

– Do not use the telephone or ring doorbells.

▶ Turn off the gas at the meter or regulator
▶ Open windows and doors
▶ Warn your neighbours and leave the building
▶ Prevent anyone from entering the building.
▶ Move well away from the building: call Emergency Services
▶ LPG boilers: Call the supplier’s number on the side of the 

gas tank

Boiler Operation

This appliance can be used by children aged 
from 8 years and above and persons with 
reduced physical, sensory or mental capabilities 
or lack of experience and knowledge, if they 
have been given supervision or instruction 
concerning use of the appliance in a safe way 
and understand the hazards involved. Children 
shall not play with the appliance. Cleaning and 
user maintenance shall not be made by children 
without supervision.

Combustible and Corrosive Materials

Chemically aggressive substances can corrode the boiler and 
invalidate any guarantee.

Do not store or use any combustible materials (paper, 
thinners, paints, propellants, cleaning agents etc.) inside 
the cupboard containing the boiler or within the vicinity of 
the appliance.

Fittings and Modifications

Only a competent registered gas engineer, such as a Gas Safe 
registered engineer or British gas engineer can remove the 
boiler’s inner combustion chamber cover and carry out any 
work, in accordance with the Gas Safety (Installation and Use) 
Regulations.

Do not remove the inner combustion chamber cover. 

Any misuse or unauthorised modifications to the boiler, flue or 
associated accessories and heating system will invalidate the 
guarantee.

Do not modify the boiler or flue system in any way.

Worcester, Bosch Group accepts no liability arising from any 
such actions. This does not affect your statutory rights.

Cleaning the boiler case

Use a damp, soft cloth to clean the outer painted metal case of 
the boiler, do not use chemicals or abrasive materials.

Safety instructions in this document are 
framed and identified by a warning triangle 
which is printed on a grey background. 

Notes contain important information in cases 
where there is no risk of personal injury or 
material losses and are identified by the symbol 
shown on the left.

Symbol

Meaning

1.

a numbered step in an action sequence

a step in an action sequence

a  list  entry

a list entry (second level)

Содержание Greenstar FS 30CDi ErP

Страница 1: ...EALED OR OPEN VENT CENTRAL HEATING SYSTEMS 6 720 818 078 2015 12 The appliances are for use with Natural Gas or L P G Cat II 2H3P type C13 C33 C53 C93 Natural Gas FS 30CDi ErP Regular GC number 41 406...

Страница 2: ...y efficient offering you economical running costs and value for money It sits in SEDBUK 2005 Band A scoring highly in SEDBUK 2009 and is therefore among the top energy rated boilers available There is...

Страница 3: ...ved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Combustible and Corrosive Materials Chemically aggressive substances can...

Страница 4: ...etedbytheinstalleratthetimeofinstallation Itconfirms that the boiler hasbeen installed and commissioned according to the manufacturer s instructions The logbook provides space for the recording of reg...

Страница 5: ...oiler controls Boiler Controls 1 Master switch for ON OFF 6 Not used 2 Power ON and fault indicator blue 7 Central heating temperature control 3 Boiler display 8 Service Engineer button only 4 Reset b...

Страница 6: ...0 Fig 3 Settings for the central heating temperature with approximate temperatures 3 2 1 Controlling the central heating Central heating systems must be controlled effectively using a programmer or ti...

Страница 7: ...protection Leave master switch on 1 Turn the central heating temperature control 7 to frost protection 3 3 1 Frost protection for the heating system If remote pipe work is likely to be subject to free...

Страница 8: ...ndicator 2 will stop flashing The boiler will function normally dependent on programmer and room thermostat settings 6720808851 05 1Wo 1 2 3 4 5 6 max reset eco 3 2 4 If the fault cannot be cleared by...

Страница 9: ...ce with the addition of cupboards shelves etc next to the boiler item Minimum distance requirements for compartments 1 Overall height of compartment 2 Overall depth of compartment 3 Overall width of c...

Страница 10: ...unventilated compartment or an airing cupboard then ventilation must be provided as described in BS 5440 A minimum of two air vents of equal size must be fitted one at low level and another at high l...

Страница 11: ...yed then it will be necessary to contact the Worcester Bosch Group This table gives information on basic operating system problems Problem Cause Remedy EA fault code flashing on display No gas supply...

Страница 12: ...up Appointments Team see back cover for details Contact your installer in order to find a permanent solution to the problem When calling Worcester Bosch Group you may be asked for the error code This...

Страница 13: ...which our products are sold to ensure optimum recycling All of our packaging materials are environmentally compatible and can be recycled 9 Tips on energy saving Heating economically The boiler provid...

Страница 14: ...f this boiler is fitted to a sealed system and water leaks are found or if excessive bleeding is required then a service engineer must be contacted to inspect the installation and rectify any fault On...

Страница 15: ...ed by faulty installation neglect misuse or accidental damage or the non observance of the instructions contained in the Installation and Users Instructions leaflets viii that the appliance has been u...

Страница 16: ...9 SPARES 0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a bra...

Отзывы: