Terminal elbow fitting

Terminal elbow (

 figure 43

▶ Remove and retain the retaining screws [2] and discard the terminal 

end [3].

▶ Fit the terminal elbow [1] to the terminal outlet and set the rotation of 

the terminal elbow depending on the plume installation option 
required.

▶ Secure the terminal end [1] with the screws [2] removed previously.

Fig. 43   Plume manangement terminal elbow

Extension fitting

Extension tube - Vertical(

 figure 44)

▶ Push the 45° elbow [4] fully into the terminal elbow [3], the stop tabs 

set the depth and allow for expansion.

▶ Push the second 45° elbow fully into the first, the stop tabs set the 

depth and allow for expansion. 

▶ Orient the 45° elbows to bring the extension close to the wall to allow 

a support clamp to be fitted.

▶ Secure the extension [2] to the wall with the support clamp and 

screws provided [1].

Extension tube - at 45° with additional elbow (45° elbow example 

 

figure 44)
▶ Push the 45° elbow [4] fully into the terminal elbow [3], the stop tabs 

set the depth and allow for expansion.

▶ Push the second 45° elbow fully into the first, the stop tabs set the 

depth and allow for expansion. 

▶ Orient the 45° elbows to bring the extension close to the wall to allow 

a support clamp to be fitted.

▶ Push the extension tube [2] fully into the 45° elbow [3], then 

withdraw the tube approximately 10mm to allow for expansion.

▶ Secure the extension [2] to the wall with the support clamp and 

screws provided [1].

▶ Push the 45° terminal elbow [4] fully into the extension tube [2], the 

stop tabs set the depth and allow for expansion.

▶ Further extensions are fitted in the same way as previously 

described.

Fig. 44   Plume extension fitting

Discharge elbow fitting

Outlet assembly (vertical orientation

 figure 45)

▶ Secure the extension [4] to the wall with the support clamp and 

screws provided [3].

▶ Push the outlet assembly elbow [1] fully into the extension tube [4], 

the stop tabs set the depth and allow for expansion.

▶ Rotate the outlet assembly [1] to the required direction permitted.
▶ Secure the outlet assembly elbow [1]to the extension [4] with the 

self-tapping screw [2] provided.

Outlet assembly (angled orientation

 figure 45)

▶ Secure the extension [4] to the wall with the support clamp and 

screws provided [3].

▶ Push the outlet assembly elbow [1] fully into the extension tube [4], 

the stop tabs set the depth and allow for expansion.

▶ Rotate the outlet assembly elbow [1] to the required direction 

permitted.

0010031937-001

3

±80°

2

1

2

±80°

2

1

4

3

0010032581-001

2

1

Содержание Greenstar Condensfit II

Страница 1: ...6 721 819 755 2019 12 UK IE Flue kit installation instructions Wall mounted gas condensing appliance flue Greenstar Condensfit II 0010032455 001 60 100 Horizontal flue kit High rise 7 733 601 221...

Страница 2: ...and safety instructions 2 1 1 Explanation of symbols 2 1 2 General safety instructions 2 1 3 Requirements 3 2 Product Information 4 2 1 Standard package 4 2 2 60 100mm flue accessories 4 3 Pre install...

Страница 3: ...essories with this flue kit Replacing an existing flue When replacing an existing Condensfit II flue on an appliance Ensure it is the correct flue system for the appliance as we have a separate flue s...

Страница 4: ...required when connecting the horizontal flue kit for higher level flue discharge compared to the standard 90 flue elbow Fig 4 Accessories 3 Pre installation 3 1 Pre Installation WARNING Flue joints an...

Страница 5: ...ns manual for the appliance Thehorizontalfixedfluelengthcanbereducedforaneffectivelength L of less than 860mm if required Measure the flue length L from the centre line of the flue outlet or flue elbo...

Страница 6: ...ntre of appliance flue outlet to wall Table 3 Dimensions when using 45 elbow offset to wall 45 Elbow offset from wall dimension High level horizontal Figure 11 shows a possible application for a 45 el...

Страница 7: ...to damage the tubes remove the unwanted sections 2 chamfer the edge of the plastic inner tube and remove any burrs from both tube sections Fig 13 Cutting an extension tube 3 2 4 High level horizontal...

Страница 8: ...ue 2 fully into the flue elbow 3 Ensure that words TOP 4 on the flue terminal are at the top Securethefluetotheflueelbowwiththetwo selfdrilling screws 5 through the two pre formed holes in the flue el...

Страница 9: ...the silicone grease provided with the extension kit Drill two pilot holes through the outer flue tube of extension 4 and 90 elbow 1 Securethe90 elbow 1 intotheextensionpiece 4 withthescrews 3 provided...

Страница 10: ...e plume redirection control Alternatively a complete plume management system can be fitted to the flue terminal Re directing the flue discharge NOTICE Damage to the flue or terminal outlet The flue te...

Страница 11: ...lbow must have a minimum of a 10 fall back to the appliance for proper disposal of condensate stop tabs in the elbow ensure that fall back is not less than 10 Any further runs after an elbow must be a...

Страница 12: ...l plume management kit example Fig 28 Extended option 5 2 4 Offset plume management kit example Fig 29 Offset option 5 2 5 45 Elbow offset plume management kit example Fig 30 45 offset option 4 Suppor...

Страница 13: ...he exclusion zone for plume discharge The discharge must be outside this zone Fig 32 Under a balcony overhang option 5 2 8 Extended plume management kit under a balcony The shaded area is the exclusio...

Страница 14: ...ength L which includes the effective length of any elbows plus the straight flue lengths Once the length L is known find that value in the relevant appliance Installation instruction to determine the...

Страница 15: ...into the outlet assembly 2 then withdraw the tube approximately 10mm to allow for expansion Fig 38 5 3 2 Plume management elbows Addingadditionalelbowstothestandardplumemanagementkitsystem reduces th...

Страница 16: ...n be 3 NOTICE Damage to flue or terminal outlet Do not rotate the complete flue terminal assembly The flue terminal outlet has built in stops to limit rotation for horizontal fluing This prevents unwa...

Страница 17: ...nsion Orient the 45 elbows to bring the extension close to the wall to allow a support clamp to be fitted Push the extension tube 2 fully into the 45 elbow 3 then withdraw the tube approximately 10mm...

Страница 18: ...all plug Screw in the support clamp into the balcony overhang plug to the distance shown in figure 46 Push the extension tube 4 fully into the outlet assembly 2 then withdraw the tube approximately 10...

Страница 19: ...ated in the appliance Installation and maintenance Instructions NOTICE Painting Do not paint the plume management kit 6 2 Spare parts Replacement wall mounted horizontal flue components Table 7 Spare...

Страница 20: ...Kingdom Tel 0330 123 9559 worcester bosch co uk TECHNICAL SUPPORT 0330 123 3366 RENEWABLE SUPPORT 0330 123 9229 CONTROLS AND CONNECTIVITY TEAM 0330 123 3641 APPOINTMENTS 0330 123 9339 SPARES 0330 123...

Отзывы: