Worcester Greenstar Comfort I RF Скачать руководство пользователя страница 3

3

Key to symbols and safety instructions

Comfort I– 6720810964 (2014/07)

1

Key to symbols and safety instructions

1.1

Key to symbols

Warnings

The following keywords are defined and can be used in this 
document:

NOTICE

 indicates a situation that could result in damage to 

property or equipment.

CAUTION

 indicates a situation that could result in minor to 

medium injury.

WARNING

 indicates a situation that could result in severe 

injury or death.

DANGER

 indicates a situation that will result in severe 

injury or death.

Important information

Additional symbols

Abbreviations

Definitions (DST/BST)

Daylight Saving Time (DST) and British Summer Time (BST) 
begins on the last Sunday in March at 1:00am GMT and clocks 
are put forward by one hour.
British Summer Time (BST) ends on the last Sunday in October 
at 2:00am BST and the clocks are put back by one hour.

1.2

General safety instructions

These installation instructions are intended for heating 
engineers, and electricians.
▶ Read any installation instructions (boiler, heating controls, 

etc.) carefully before starting the installation.

▶ Observe the safety instructions and warnings.
▶ Observe national and regional regulations, technical rules 

and guidelines.

▶ Record all work carried out.

Appliance operation

This appliance can be used by children aged from 8 years and 
above and persons with reduced physical, sensory or mental 
capabilities or lack of experience and knowledge if they have 
been given supervision or instruction concerning use of the 
appliance in a safe way and understand the hazards involved. 
Children shall not play with the appliance. Cleaning and user 
maintenance shall not be made by children without 
supervision. (BS EN 60335-1 2012)

Installation, commissioning and servicing

Installation, commissioning and servicing must only be carried 
out by a competent engineer.

▶ Only use original spares.

Electrical work

Electrical work must only be carried out by a qualified 
electrician.

▶ Before starting electrical work: 

– Isolate the mains electrical supply and secure against 

unintentional re-connection.

– Check  for  zero  voltage.

▶ Also observe connection diagrams of other system 

components.

Handover to the user

When handing over, instruct the user how to operate the 
heating system and inform them about its operating 
conditions.

▶ Explain how to operate the heating system and draw the 

user's attention to any safety-relevant action.

▶ Explain that modifications and repairs must only be carried 

out by an authorised contractor.

▶ Advise the user to have the system serviced annually by a 

competent engineer.

▶ Leave this instruction manual with the user or at the 

appliance.

Warnings in this document are identified by a 
warning triangle printed against a grey 
background.
Keywords at the start of a warning indicate the 
type and seriousness of the ensuing risk if 
measures to prevent the risk are not taken.

This symbol indicates important information 
where there is no risk to people or property.

Symbol

Explanation

Step in an action sequence

 

Cross-reference to another part of the document

List entry

List entry (second level)

CH

= Central Heating

DHW

= Domestic Hot Water

RF

= Radio Frequency

DST

= Daylight Savings Time

BST

= British Summer Time

GMT

= Greenwich mean time

RPB

= Rotary Push Button

Содержание Greenstar Comfort I RF

Страница 1: ...structions Radio Frequency Twin Channel Programmer Receiver and Room Thermostat Greenstar Comfort I RF 6720810964 00 1Wo select advance select advance menu For EMS compatible Worcester Greenstar conde...

Страница 2: ...on 10 4 1 Programmer Receiver 10 5 Programmer Receiver settings 11 5 1 User 11 5 1 1 Heating 11 5 1 2 Hot water 12 5 1 3 Holiday function 12 5 1 4 Info 12 5 1 5 Setting 12 5 2 Installer 14 5 3 Key loc...

Страница 3: ...nderstand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision BS EN 60335 1 2012 Installation commissioning...

Страница 4: ...eiver has up to three sets of ON and OFF times that can be set to control central heating and hot water The unit has user and installer menus to allow the setting of the time programs monitoring of sy...

Страница 5: ...klit this will reduce the drain on battery power which will maximise the life of the batteries Fig 2 RF Room thermostat 1 Display Currentroomtemperatureindegrees centigrade C Newtemperaturesetpointswh...

Страница 6: ...dServicing instructionmanualformountingtheProgrammer Receiverinto the boiler fascia Wall mounted Programmer Receiver Choose a convenient wall location approximately 1 2 metres from the floor to mount...

Страница 7: ...r Receiver Installer menu Radio settings Pair The Room thermostat and Programmer Receiver must be in the same mode of pairing The Programmer Receiver Pairing Unpairing function is found under the Inst...

Страница 8: ...laying the current room temperature to move to the next higher level press the knob for more than three seconds and when the bars are displayed release the knob To leave the menu and display current r...

Страница 9: ...with the Room thermostat contains 2 x countersunk screws 2 x plastic wall plugs Drill the two holes to suit the wall plugs Fit the wall plugs Fit the screws but leave a sufficientamount proud to allo...

Страница 10: ...timeprogram the black markers indicate half hour time periods The flashing black marker indicates the current time position in the programmed sequence either in the ON or OFF period Fig 10 Display ele...

Страница 11: ...ation is the same Select the desired day s using the knob Press the knob to select the first Heating ON setting The hours flash Turn the knob to select the desired hours setting Press the knob to conf...

Страница 12: ...he holiday function Press the menu key for more than three seconds to enter user menus and select Holiday ON will be displayed Press the knob and ON flashes turn the knob to select OFF Press the knob...

Страница 13: ...Contrast this function allows you to adjust the contrast of the screen bydefaultitissetto10 The current contrast flashes Turn the knob to select from 0 to 20 the desired level adjusting the contrast...

Страница 14: ...lts is displayed with the fault code and occurrence date The fault screens can be scrolled through using the knob If no faults have occurred the text No fault will be displayed b Landlord func This fu...

Страница 15: ...g that is RF pairing of the devices in the system Turn the knob to display Unpairing or Pairing IfPairingischosen presstheknobandpairingisdisplayed withadvancingbars whenthepairingbetweenthedevices ha...

Страница 16: ...wtemperaturesettingflashingfor three seconds and then OFF flashing for three seconds Low battery The battery symbol indicates the batteries require replacing within two months refer to section 9 1 Bur...

Страница 17: ...s a precision temperature gauge meter available the display can be offset by 5 C to compensate The default value is 0 0 C Turn the knob to select E 1 Fig 20 Temperature sensor adjustment Press the kno...

Страница 18: ...d a zero will be displayed indicating that no units are connected Press the knob for more than three seconds to return to the previous level rF 1 Press the knob until the three bars are displayed and...

Страница 19: ...RF signal or pairing fault All units powered and not showing low battery symbol Repeat pairing A23 1003 Room stat internal sensor failure Internal room temperature sensor out of valid range Replace R...

Страница 20: ...eplace the batteries with the same type AAA 1 5V alkaline Fig 22 Low battery indication Battery access To remove the Room thermostat from the wall mounting plate 1 Insert a suitable flat bladed screwd...

Страница 21: ...ycled Electrical and electronic equipment Scrap electrical and electronic equipment must be collected separately and returned to an environmentally compatible recycling facility European Directive on...

Страница 22: ...22 Comfort I 6720810964 2014 07 Notes...

Страница 23: ...23 Comfort I 6720810964 2014 07 Notes...

Страница 24: ...0330 123 9779 LITERATURE 0330 123 9119 TRAINING 0330 123 0166 SALES 0330 123 9669 Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 0330 123 9559 Worcester Bosch Group is a brand name...