Settings in the service menu
Greenstar 8000 Life – 6720883865 (2019/02)
44
7
Settings in the service menu
Many appliance functions can be set and checked in the service menu.
7.1
Operating the service menu
Opening the service menu
▶ Press the DHW key and the Heating key simultaneously until the
service menu appears.
Closing the service menu
▶ Press the DHW key or the Heating key.
-or-
▶ Press the
d
key.
Navigating through the menu
▶ To highlight a menu or a menu item, press the
key or the
key.
▶ Press the
OK
key.
The menu or the menu item is displayed.
▶ To return to the next higher menu level, press the
d
key.
Changing the setting values
▶ Select the menu item with the OK
key.
▶ To select the desired value, press the
or the
key.
The new value will be saved after 5s or after pressing the
OK
key.
Exiting the menu item without saving values
▶ Press the
d
key.
The value is not saved.
7.2
Service menu
7.2.1
Service functions overview
Menu A (L.A) Benchmark menu
▶ Press the
(
key and
*
key at the same time, until
L.A
is displayed.
▶ To confirm the selection: Press the
OK
key.
▶ Select and set the service function.
Table 17 Benchmark menu
Menu 1 (L.1) Info menus
▶ Press the
(
key and
*
key at the same time, until
L.A
is displayed.
▶ Keep pressing the arrow key
, until
L.1
is displayed.
▶ To confirm the selection: Press the
OK
key.
▶ Select and set the service function.
The factory settings are depicted as
highlighted
in the following table.
Service function L.A
Unit
More information
A-A5 Actual temperature
°C
Flow temperature at the flow temperature sensor
Service function L.1
Unit
More information
1-A1 Current status
Status code.
1-A2 Current fault
Fault code (
1-A3 Maximum heating output
%
The maximum thermal output can be reduced via the service
function 3-b1.
1-A5 Actual temperature
°C
Flow temperature at the flow temperature sensor.
1-A6 Set flow temperature
°C
Setting value of the flow temperature demanded by the heating
controller.
1-A7 Temperature at hydraulic point
°C
This service function will only be available, if service function 2-A1
is activated.
1-b2 DHW flow rate
l/min
Hot water flow rate.
1-b3 DHW actual temperature
°C
Actual hot water temperature.
1-b4 Hot water temperature outlet
°C
Hot water temperature.
1-b7 DHW set temperature
°C
Setting value of the hot water temperature demanded by the
heating controller.
1-b8 Maximum heat output
%
Maximum heating output.
1-C1 Ionisation current
A
1-C2 Pump modulation
%
Actual heating pump modulation.
1-C4 Outside temperature
°C
Current outside temperature (with outside temperature sensor
connected)
1-C6 System pressure
bar
Current system pressure
1-d1 Collector temperature
°C
Is only displayed, if a solar module is connected.
1-d2 Cylinder temperature bottom
°C
Is only displayed, if a solar module is connected.
1-d3 Collector pump
%
Is only displayed, if a solar module is connected.
1-d4 Solar fault
Is only displayed, if a solar module is connected.
Fault code
1-E1 Control device version
Software version of the control unit.
1-E2 Programmer unit version
Software version of the programmer.
1-E3 Code plug number
Coding plug number.
1-E4 Code plug version
Coding plug version.
1-EA Software version of the equipment electronics (main version)
–