SAFETY PRECAUTIONS  

INSTALLATION REGULATIONS

OIL SMELLS, LEAKS OR FUMES FROM THE APPLIANCE:

4

Extinguish any naked flames.

4

Open windows and doors.

4

Isolate the electrical supply.

4

Isolate the fuel supply to the boiler.

4

Rectify fault.

HEALTH & SAFETY:

The appliance contains no asbestos and no substances have been used in the construction
process that contravene the COSHH Regulations (Control of Substances Hazardous to Health
Regulations 1988). Where applicable, the CE mark indicates compliance with relative EU
Directives.

COMBUSTIBLE AND CORROSIVE MATERIALS:
Do not

store or use any combustible materials (paper, thinners, paints etc.) inside or within the

vicinity of the appliance.
The combustion air must be kept clear of chemically aggressive substances which can corrode
the appliance and invalidate any warranty.

FITTING & MODIFICATIONS:

Fitting the appliance and any controls to the appliance may only be carried out by a competent
engineer in accordance with these instructions and the relevant Installation Regulations.
Flue systems must not be modified in any way other than as described in the fitting instructions.
Any misuse or unauthorised modifications to the appliance, flue or associated components and
systems could invalidate the warranty. The manufacturer accepts no liability arising from any
such actions, excluding statutory rights.

SERVICING:

Advise the user to have the system regularly serviced by a competent, qualified engineer (such
as OFTEC registered personnel) using approved spares, to help maintain the economy, safety
and reliability of the appliance.

Failure to install appliances correctly could lead to
prosecution.

COMPLYING WITH THE BUILDING
REGULATIONS:

The boiler and flue form part of the controlled
services for the building. It is law that all
controlled services for buildings must comply
with building regulations. You must be able to
satisfy your Local Authority Building Control
Body (LABC) that the work carried out
concerning the installation and commissioning of
the heating appliances has been carried out to a
satisfactory standard.

OFTEC operate a competent persons scheme
and registered installers are able to certify that
their work complies with building regulations.
Under the scheme;

l

OFTEC must be informed about every 
installation.

l

OFTEC will issue a building regulations 
compliance certificate to the householder and 
will notify the LABC.

OFTEC provide controlled document forms
CD10 and CD11 for use during installation and
commissioning resectively.

Other organisations operate self-certification
schemes e.g. NAPIT and BESCA Ltd. and it may
be possible for installers who are members of
these organisations to self certify their work.

Alternatively you must submit a building control
notice to the LABC before installing any boiler.
The LABC will then arrange regular inspection
visits during the work to ensure that the
installation complies with the regulations.

The appliance must be installed by a competent
person. The person installing the appliance should
be aware of the Health and Safety at Work Act and
take appropriate action to ensure that the
regulations are adhered to. In order to give
optimum efficiency and trouble free operation the
appliance must be commissioned by a qualified
OFTEC engineer.

The compliance with a British Standard does not, in
itself, confer immunity from legal obligations. In
particular the installation of this appliance must be
in accordance with the relevant requirements of the
following British Standards and regulations in
respect of the safe installation of equipment.
BS 5410: part 1: Code of practice for Oil Fired
Boilers.
The Building Regulations Part J and L1 England
and Wales; Part F and Part J Section III Scotland;
Part L and Part F Northern Ireland.
Local water company bye-laws.
The Control of Pollution (Oil) Regulations.
OFTEC Standards.
Where no specific instruction is given, reference
should be made to the relevant codes of practice.

Содержание 7 716 190 031

Страница 1: ...IT INSTALLATION GB For use with the following Greenstar oil fired appliances Greenstar Utility 18 25 Greenstar Danesmoor 18 25 Greenstar Heatslave 12 18 18 25 25 32 Greenstar Camray Kitchen 12 18 18 2...

Страница 2: ...LICABLE TO THE WORCESTER APPLIANCE MODEL S STATED ON THE FRONT COVER OF THIS MANUAL ONLY AND MUST NOT BE USED WITH ANY OTHER MAKE OR MODEL OF APPLIANCE THE INSTRUCTIONS APPLY IN THE UK ONLY AND MUST B...

Страница 3: ...ROOM SEALED FLUE EXTENSION COMPONENTS 7 PRE INSTALLATION CONVENTIONAL FLUE 8 ROOM SEALED FLUE OPTIONS 9 10 INSTALLATION CONVENTIONAL VERTICAL FLUE 11 ROOM SEALED FLUE MEASURING CUTTING 12 ROOM SEALED...

Страница 4: ...gs must comply with building regulations You must be able to satisfy your Local Authority Building Control Body LABC that the work carried out concerning the installation and commissioning of the heat...

Страница 5: ...FLUE COMPONENTS CF VERTICAL FLUE KIT Part Number 7 716 190 036 including A ADAPTOR 80mmO to 100mmO ADAPTOR 80mmO to 103mmO B ELBOW C BOLT AND SOLVENT FREE GREASE SACHET D AIR INLET SILENCER CAMRAY ONL...

Страница 6: ...LED VERTICAL FLUE COMPONENTS 80 125mmO RS VERTICAL FLUE KIT Part Number 7 716 190 032 including A TERMINAL ASSEMBLY B ELBOW C CLAMP BRACKET D FIRE STOP PLATE WITH SCREWS WASHERS AND WALL PLUGS E PIPE...

Страница 7: ...DAPTOR C ELBOW 80 125mmO D CLAMP BRACKET E FIRE STOP PLATE WITH SCREWS WASHERS AND WALL PLUGS F PIPE CLAMP WITH SCREWS WASHERS AND WALL PLUGS G DRILL PACK CONTAINING 3 3mm HSS JOBBER DRILL AND SOLVENT...

Страница 8: ...TERMINAL ASSEMBLY C CLAMP BRACKET D WALL PLATES WITH SCREWS WASHERS AND WALL PLUGS E WALL SEAL F DRILL PACK CONTAINING 3 3mm HSS JOBBER DRILL AND SOLVENT FREE GREASE SACHET ROOM SEALED HORIZONTAL FLU...

Страница 9: ...ELBOW Part Number 7 716 190 035 including D 45 ELBOW x2 E SOLVENT FREE GREASE PACK CONTAINING 2 No 8 SCREWS GREASE SACHET 100 150mmO RS FLUE EXTENSION Part Number 7 716 190 045 including A EXTENSION T...

Страница 10: ...Never reduce the flue diameter from the boiler take off point CF SIZING 12 18 and 18 25 100 103mmO Dependent on external diameter of flue system used 25 32 130mmO Because the flue operates at a lower...

Страница 11: ...3 to allow the condensate to drain back to the boiler Greenstar Danesmoor Kitchen 12 18 18 25 25 32 4000 6000 80 125 Greenstar Danesmoor Utility 12 18 18 25 25 32 4000 6000 80 125 Greenstar Heatslave...

Страница 12: ...y 25 32 100 150mmO Danesmoor Heatslave L 6000mm E Bx6 Camray 12 18 18 25 L 8000mm E Bx8 Camray 25 32 L 8000mm E Bx8 Camray 25 32 L 7000mm E D Bx7 Camray 25 32 L 7000mm E Bx7 A Horizontal terminal B St...

Страница 13: ...dels fit the 100mm adaptor F then the 100 130mm adaptor G not supplied part number 7 716 190 065 4Fit proprietory flue E or H not supplied according to the manufacturers instructions 4Connect to adapt...

Страница 14: ...h required from the end of the terminal flue outlet and cut square taking care not to distort the tubes 4Remove any burrs and chamfer the outer edges of the tubes to assist ease of connection and prev...

Страница 15: ...F into the boiler flue outlet ensuring a good fit to seal G 4 Secure flue F to boiler outlet with clamp E 4 Secure flue support bracket s where used 3 Outlets A B and C 4 Slide flue clamp E over the...

Страница 16: ...rtical adaptor MUST be fitted vertically at the lowest point of the vertical section of the flue Failure to fit the adaptor vertically will cause the condensate pool within the flue and will adversely...

Страница 17: ...supplied to weatherproof terminal exit to roof 4 Secure fire stop plates B to ceiling with screws provided 3 Horizontal terminal only 4 Fit terminal C through the flue opening in the wall F to the out...

Страница 18: ...N www worcester bosch co uk EXCELLENCE COMES AS STANDARD Worcester Bosch Group Cotswold Way Warndon Worcester WR4 9SW Tel 01905 754624 Fax 01905 754619 8 716 106 261b 01 07 Worcester Bosch Group is a...

Отзывы: